Outdoor Fan Motor Operation; Airflow Direction - Panasonic CS-ME5RKUA Service Manual

Table of Contents

Advertisement

10.8

Outdoor Fan Motor Operation

Outdoor fan motor is operated with fan speed number of rotation. It starts when compressor starts operation and it
stops 30 seconds after compressor stops operation.
Compressor
Outdoor Fan
10.9

Airflow Direction

There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
10.9.1
Vertical Airflow
Operation Mode
Heating
Cooling
Soft Dry
Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane
will shift to close position.
Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
10.9.2
Horizontal Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
ON
ON
Fan Speed
30 sec
Airflow Direction
Auto with Heat Exchanger
Temperature
Manual
Auto
Manual
Auto
Manual
C
136.4°F
B
96.8°F
A
Indoor Heat Exchanger
Temperature
Figure 1
OFF
OFF
A
B
C
1
2
122°F
3
86°F
4
5
Figure 2
24
ON
ON
Vane angle (°)
1
2
3
4
20
57
32
20
32
45
57
20 ~ 45
20
26
32
37
20 ~ 45
20
26
32
37
Side View
140°
Close position
5
68
45
45