Hide thumbs Also See for SigNET 200:

Advertisement

SigNET 200/300 User Guide
SigNET 200/300

User Guide

E-LAB-1543
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SigNET 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Europlex SigNET 200

  • Page 1: User Guide

    SigNET 200/300 User Guide SigNET 200/300 User Guide E-LAB-1543...
  • Page 2 Further Europlex reserve the right to revise this publication and to make changes from time to time in the contents hereof without the obligation of Europlex to notify any person of any such revision.
  • Page 3: Table Of Contents

    SigNET 200/300 User Guide Table of Contents INTRODUCING THE SIGNET 200/300 SYSTEM ......................4 USING THE KEYPAD ................................4 ............................5 SING THE EYPAD NTERFACE SETTING, UNSETTING, AND RESTORING THE SYSTEM ..................6 : FULLSET ............................6 ETTING THE YSTEM : PARTSET A ..........................
  • Page 4: Introducing The Signet 200/300 System

    1. Introducing the SigNET 200/300 System The SigNET 200/300 system must be installed by a qualified installation engineer. When the installation has been completed, the engineer provides users with passwords to set or unset and configure the system as required.
  • Page 5: Using The Keypad Interface

    SigNET 200/300 User Guide Using the Keypad Interface Figure 2 – Keypad Interface TOP LINE OF DISPLAY BOTTOM LINE OF DISPLAY In the IDLE state, this line is blank. In the IDLE state, this line displays the current date and...
  • Page 6: Setting, Unsetting, And Restoring The System

    4, 5, or 6 digits, depending upon the Grade the system has been programmed to. A user’s ability to see menus and options available on the SigNET 200/300 PARTSET A? system is programmed by the installation engineer. If users cannot see an option...
  • Page 7: Failing To Set The System

    FIRST ZONE Restoring an Alarm Activation (Alert) Alarm conditions on the SigNET 200/300 are indicated on the Keypad by a flashing yellow Alert LED (see Section 2, Using the Keypad) and by activation of the buzzer. The Keypad displays the location and nature of the alert condition.
  • Page 8: Using X10 Features

    SigNET 200/300 User Guide Using X10 Features X10 is a technology that allows peripheral devices, such as lights, heaters, or appliances, to be controlled by the system and system events can be used to trigger outputs on the X10 devices. For example, a hall light could be configured to turn on when the front door of the house is opened.
  • Page 9: Inhibiting A Zone

    SigNET 200/300 User Guide Inhibiting a Zone Zones on the system can be manually inhibited from the Keypad. Inhibiting a MENUS zone removes that zone from the system for 1 alarm set period only. EXIT SELECT 1. Enter a valid user code.
  • Page 10: Allowing Engineer/Manufacturer Access

    SigNET 200/300 User Guide Allowing Engineer/Manufacturer Access When engineer or manufacturer access has been allowed, the Keypad displays MENUS the text ENGINEER ENABLE or MANUFACT ENABLE. Once access has been EXIT SELECT granted, the user cannot access the system until the engineer has logged off.
  • Page 11: Viewing The Event Log

    4. Choose to enable or disable the chime function by toggling between the EXIT SELECT two options. Using SMS For instructions on using the SMS feature, visit the Downloads section of Europlex’s web site at www.europlex- signet.com/downloads and download the SMS User Guide. E-LAB-1543...
  • Page 12: Appendix A: Adding New Users

    SigNET 200/300 User Guide Appendix A: Adding New Users New users can be added through the Keypad. Only master type users can MENUS add new users, edit user profiles, or delete current users. EXIT SELECT To add a new user: 1.
  • Page 13: Appendix B: Standard User Settings

    Appendix B: Standard User Settings The operational features of the SigNET 200/300 system are described below. The installation engineer will inform users of their user rights assigned to each user profile. Depending on how the system has been programmed, users may have rights to all or some of these features.
  • Page 14: Appendix C: User Configuration And Test Options

    Master This feature allows users to set up the SMS messaging service if a modem is installed on the system. For instructions on using the SMS feature, visit the Downloads section of Europlex’s web site at www.europlex-signet.com/downloads and download the SMS User Guide.
  • Page 15: E-Lab

    SigNET 200/300 User Guide Zone Chart Zone # Description E-LAB-1543...

This manual is also suitable for:

Signet 300

Table of Contents