Download Print this page

Dell Precision 620 User Manual page 102

Hide thumbs Also See for Precision 620:

Advertisement

Write fault on
selected drive
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.
System Beep Codes
When errors occur during a boot routine that cannot be reported on the monitor, your computer may emit a series of beeps that identify the
problem. The beep code is a pattern of sounds: for example, one beep, followed by a second beep, and then a burst of three beeps (code 1-1-3)
means that the computer was unable to read the data in nonvolatile random-access memory (NVRAM). This information is invaluable to the Dell
support staff if you need to call for technical assistance.
When a beep code is emitted, write it down on a copy of the
problem by looking up the meaning of the beep code, use the
problem, see
"Getting
Help" for instructions on obtaining technical assistance.
Table 2. System Beep Codes
Code
Cause
1-1-2
Microprocessor register failure
1-1-3
NVRAM
1-1-4
ROM BIOS checksum failure
1-2-1
Programmable interval timer
1-2-2
DMA initialization failure
1-2-3
DMA page register read/write failure
1-3
Video Memory Test failure
1-3-1
RIMMs not being properly identified or used
1-3-2
No RIMM detected
1-3-3 through
RIMMs not being properly identified or used
2-4-4
3-1-1
Slave DMA register failure
3-1-2
Master DMA register failure
3-1-3
Master interrupt mask register failure
3-1-4
Slave interrupt mask register failure
3-2-2
Interrupt vector loading failure
3-2-4
Keyboard Controller Test failure
3-3-1
NVRAM power loss
3-3-2
NVRAM configuration
3-3-4
Video Memory Test failure
3-4-1
Screen initialization failure
3-4-2
Screen retrace failure
3-4-3
Search for video ROM failure
4-2-1
No time tick
4-2-2
Shutdown failure
4-2-3
Gate A20 failure
4-2-4
Unexpected interrupt in protected mode
4-3-1
Memory failure above address 0FFFFh
4-3-3
Timer-chip counter 2 failure
4-3-4
Time-of-day clock stopped
4-4-1
Serial or parallel port test failure
4-4-2
Failure to decompress code to shadowed
memory.
hard-disk drive.
Diagnostics Checklist
Dell Diagnostics
and then look it up in Table 2. If you are unable to resolve the
to identify a more serious cause. If you are still unable to resolve the
Action
See
"Getting
Help" for instructions on obtaining technical assistance.
Run the System Board Devices tests in the
Run the System Board Devices tests in the
Run the System Board Devices tests in the
Run the System Board Devices tests in the
Run the System Board Devices tests in the
Run the VESA/VGA Interface tests in the
See
"Troubleshooting System
Memory."
Install RIMM pair or reseat RIMMs.
See
"Troubleshooting System
Memory."
Run the System Board Devices tests in the
Run the System Board Devices tests in the
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
Run the Keyboard tests in the
Help" for instructions on obtaining technical assistance.
Run the System Board Devices tests in the
Run the System Board Devices tests in the
Run the VESA/VGA Interface tests in the
Run the VESA/VGA Interface tests in the
Run the VESA/VGA Interface tests in the
Run the VESA/VGA Interface tests in the
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
Run the System Memory tests in the
See
"Getting
Help" for instructions on obtaining technical assistance.
See
"Getting
Help" for instructions on obtaining technical assistance.
Run the Serial Ports and the Parallel Ports tests in the
Run the System Board Devices tests in the
Dell
Diagnostics.
Dell
Diagnostics, if possible.
Dell
Diagnostics, if possible.
Dell
Diagnostics, if possible.
Dell
Diagnostics, if possible.
Dell
Diagnostics.
Dell
Diagnostics, if possible.
Dell
Diagnostics, if possible.
Dell
Diagnostics. Otherwise, see
Dell
Diagnostics, if possible.
Dell
Diagnostics, if possible.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.
Dell
Diagnostics.
"Getting

Advertisement

loading