i1200 Owner's Manual (2003-Current Models)
**TROUBLESHOOTING NOTE: Some scale owners (especially with the i2600) have noted that their
scale will give a MUCH more accurate calibration if calibration is performed as quickly as possible (not
pausing between steps). This is especially true in the step after you have placed the calibration weight
on the tray. If your scale is acting inaccurate after calibration, please try recalibrating 'as quickly as
possible'.
Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of scale malfunction
and inaccuracy! We test all of our scale returns from consumers. Fully 60% of consumer returns are
battery related problems. This sounds silly but it's true! A scale will perform slowly, or read inaccurately
when it has low batteries. Please replace the batteries often (and only use good quality batteries). We
include good quality batteries with all of our scales but batteries can run low in storage. If your scale
simply won't turn on while on Battery power, this is often caused by loose battery connections. Battery
prongs (terminals) are made of metal. They must be making good contact with your batteries in order
for the scale to power on. You can use a paperclip to slightly bend the battery prongs to make them
have a better connection. Also some poorly designed batteries have recessed or partially obstructed
battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead
of the metal battery terminal. A Faulty AC adaptor can cause your scale to act unstable with numbers
"jumping" all around. Please test your scale with a good set of batteries (instead of the AC adaptor) to
determine if perhaps the AC adaptor is faulty.
Due to the SS tray of the iBalance, this model is especially prone to being charged with Static Electricity.
Please discharge any static electricity if you think your scale is acting unstable.

SAFETY PRECAUTIONS

All safety messages are identified by the words warning and caution. These words mean the following:
Warning Important information to alert you to a situation that might cause serious injury and damage to
your property if instructions are not followed.
Caution
Important information that tells how to prevent
damage to the equipment.
When using the i500/i1200, the following safety
precautions should always be followed.
Warning: Use only the correct AC adaptor with the
scale. Other adaptors may cause permanent electrical
damage. The i2600 uses an adaptor that is different
from the i500 and i1200. For reference, the i2600
adaptor is pictured here:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for MyWeigh i1200

  • Page 1 Warning: Use only the correct AC adaptor with the scale. Other adaptors may cause permanent electrical damage. The i2600 uses an adaptor that is different from the i500 and i1200. For reference, the i2600 adaptor is pictured here:...
  • Page 2 For the i500 you must have an accurate 500 gram weight or a combination of weights that equals 500 grams in order to calibrate. For the i1200 there are 2 models: For the 2003 i1200 you must have an accurate 1200 gram weight or a combination of weights that equals 1200 grams in order to calibrate.
  • Page 3 2. Enter calibration mode. Press [ON/OFF] to turn the power off. Press and hold [ZERO] first, then Press [ON/OFF] while keeping the [ZERO] button depressed, the display will show the A/D value (a series of random numbers). 3. Calibration by the weight. Wait for the stable indicator to be displayed, Press [SET] the display will show "00SAVE", after 2 seconds, the display will return to the A/D value.
  • Page 4 Caution: Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction. Place your i500/i1200 on a firm weighing table so that the scale is level. (The scale will not perform accurately when it is not level.) Make sure there are absolutely NO air currents or vibrations. They can cause...
  • Page 5 Place the scale on a firm surface that is flat and level for accurate weighing. Weighing Before weighing, a several second warm up time is required after turning the power on so that the scale will function properly and accurately. Calibration may be required before weighing. Calibration is rarely needed.

Table of Contents