Unit Specifications

The unit specifications will vary among the models listed in this service manual. See chart below for unit
specifications related to the model that you are servicing.
Wine Cellar, Beverage Center & Refrigerated Drawers Unit Specifications
Cabinet Dimensions (in)
Model
Height
Width
DFUW144
DUWC144
34
23 ⅝
VUWC144
DFUR143/144
DUAR143/144
34
23 ⅝
VUAR143/144
DFRD144
DURD144
34
23 ⅞
VURD144

Serial Nameplate

The serial nameplate is located inside of the unit on the upper left hand wall. The serial number will need to be given
when inquiring about the unit or ordering parts. See illustration below for a sample serial tag with manufacturing date
code logic.
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
MODEL NO.
"A"
"D"
"C"
VOLTS
HZ
PH
R134A
OZ
TEST PRESSURE
"H"
A
DFUW, DUWC, VUWC 144
DFUR, DUAR, VUAR 143/144
DFRD, DURD, VURD 144

Before Servicing

Always disconnect power to any Viking product
before attempting to service it. Always verify that
power has been disconnected.
If the unit has been running, use caution around the
condenser and copper tubing. These areas may be
very hot.
Use caution around the condenser fins and
baseplate edges. These areas are sharp.
Refrigerant is under high pressure. Always evacuate
any system before attempting to open it.
Reasonable care and safe work methods should
be practiced when working on any Viking product.
Never work with energized electrical equipment in
wet or damp areas.
4
Power
Refrigerant
Weight
Cord
Charge
(lbs)
Length
(oz)
Depth
24 ¼
166
2.8
24 ¼
166
3.6
24 ¼
170
3.6
C
LISTED
905L
SERIAL NO.
HOUSEHOLD
REFRIGERATOR
DETAIL "B"
"E"
"F"
"G"
AMPS
BTU/HR
"J" PSI LOW SIDE
"K" PSI HIGH SIDE
B
C
Detail B
115
Detail B
115
System
Compressor
Refrigerant
Type
Control
(ft)
Capillary
7
Piston type
tube
DETAIL "B"
YYYYMMDDSSSA
YEAR
MONTH
DAY
D
E
F
60
1
440
60
1
440
Use an appropriate work area and location when
performing repairs. You will find that it is easier to
repair undercounter units if they are set on a raised
platform or workbench.
Always wear protective safety glasses and gloves
when working on any Viking product.
Any refrigerant, whether CFC, HCFC, or HFC (R-12,
R-22, or R-134a), must be recovered. Federal
regulations prohibit the intentional venting or release
of refrigerants during the service repair or disposal
of an appliance.
SMR-0003
Temperature
Condenser
Control
Fan Motor
Electronic Control
with LED display,
2.3 W 1300
thermistor input,
RPM
and Tru Protect™
ASSEMBLY SITE
SERIAL
G
H
J
3.3
2.8
140
3.3
3.6
140
© Viking Range Corporation
Evaporator
Fan Motor
12VDC
K
300