Appliance Preparation

A. Vent Collar Preparation
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during
installation. Sheet metal edges are sharp.
1. Position the pipe heat shield up against the header and
attach to header with two screws.
WARNING! Risk of Fire! Pipe heat shield must be fas-
tened to header.
2. Place a 24 inch vent section on the starting collar.
WARNING! Risk of Fire! A MINIMUM of 24 inches verti-
cal pipe is required prior to attaching any elbow to the
appliance.
3. Place the 1/8 inch thick, square fi berglass gasket over
the initial 24 inch vent section.
4. Place the fi berglass rope ring over the gasket. Ensure
both the gasket and the rope ring are seated on the top
of the appliance.
Heatilator • CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST Installation Manual • 2301-970 Rev. E • 8/14
28
BOTTOM PANEL SCREW LOCATIONS
Figure 6.1 Location of Fiberglass Rope Ring
PIPE HEAT SHIELD
FIBERGLASS ROPE RING