3.2
Service mode
Operation method
Sequence of LCD diaplay
Press the [F.SKIP] . . . . . . . . MAIN
Press the [B.SKIP] . . . . . . . . MAIN
Cancellation of service mode
No operation for ten seconds
Press the key except for [F.SKIP] or [B.SKIP] key
Insert the test disc
"TOC read" starts
Press the [CD], [SEL]
and [POWER] keys
simultaneously for 2 seconds.
"VERSION" is
indicated on the LCD.
Press the [SEL] key
"MAIN 400" is
indicated on the LCD.
Press the [F.SKIP] key
"SUB
225" is
indicated on the LCD.
Press the [F.SKIP] key
"SUB 144" is
indicated on the LCD.
Press the [F.SKIP] key
Return to normal display
(Note)
If "SUB 000" and "VCD 000"
are indicated on the LCD,
these operations are required.
MAIN 400
Main micon software version
Space
SUB
225
Sub micon software version
VCD 144
VCD/CD control IC software version
SUB
VCD/CD
MAIN
VCD/CD
SUB
MAIN
Return to normal display
(No.49837)1-25