[3] Entering and exiting the adjustment process mode

1) Unplug the AC power cord of running TV set to force off the power.
2) While holding down the "VOL(-)" and "INPUT" keys on the set at once, plug in the AC power cord to turn on the power. The letter
the screen.
3) Next, hold down the "VOL(-)" and "P(
Multiple lines of orange characters appearing on the screen indicate that the set is now in the adjustment Process mode. If you fail to enter the
adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the power. (When the power is turned off
with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
5) To remove "K" mode holding down the "VOL (-)" and "INPUT" kyes on the set at once ("K" disappears).
Caution :
Use due care in handling the information described here lest the users should know how to enter the adjustment process mode. If the
settings are tampered with in this mode, unrecoverable system damage may result.

[4] Remote controller key operation and description of display in adjustment process mode.

1. key operation
Remote controller key
P (
/
)
VOL (+ / –)
Cursor (UP/DOWN)
Cursor (LEFT/RIGHT)
INPUT SOURCE
on remote controller
OK
* Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
2. Description of display
(1) Current page/Total pages (3) Currently selected input
)" keys on the set at once.
Main unit key
P (
/
)
VOL (+ / –)
——————
——————
INPUT button
——————
(2) Current page title
[INFO]
TV
1/11
Main Version
1.XX (XX/XX/XXX)
Dev Version
XX
Dev Loader Version
XX
Pic Version
XX
TEMP SENSOR
XX
NORMAL STANDBY CAUSE
XX
ERROR STANDBY CAUSE
XX
Moving an item (line) by one (UP/DOWN)
Changing a selected item setting (+1/–1)
Turning a page (PREVIOUS/NEXT)
Changing a selected line setting (+10/–10)
Input source switching (toggle switching)
(TV→EXT1→EXT2→EXT3→EXT4→EXT5)
Executing a function
(4) Current colour TV system
Inch Setting (32 just as example, it may be: --/26/32)
(5) Destination (EURO just as example.
See Factory Init,it may be EURO, UK,
ITALY, FRANCE or RUSSIA)
AUTO 32
EURO
Adjustment process
menu header
(7) Parameters
5 – 11
K
Function
appears on

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32sa1e

Table of Contents