6.9.6

Wiring diagram

Wiring diagram for RM 7xx1 L - models and RM 7xx5 L - models
Reed contacts
(sensor switching)
lighting DC
permanently
connection DC
C
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
For operation, it is compulsory to provide the device with a permanent 12V
DC connection at terminals C/D (permanent voltage supply for the functio-
nal electronics).
D
For the RM 7XX1 L models, there is no
X106 connection (Solar S+ and D+)!
29
ignition unit
Connections:
ionisation
A = Ground heating element DC
plug
B = Plus heating element DC
C = Ground electronics
ignition
D = Plus electronics
plug
Ground
gas burner
heating element DC
valve
temp. sensor
heating element AC
Ground
B
A
mains
connection
Colours:
schwarz = black
violett = violet
braun = brown
weiss = white
grün = green
gelb = yellow
rot = red