Viessmann VITODENS 200-W Service Instructions Manual page 78

Table of Contents

Advertisement

Code 2
Heating circuit 1, heating circuit 2, heating...
Coding in the delivered condition
d7:0
Heating circuit pump
stays in control mode at
signal "External
demand"
d8:0
No heating program
changeover via extension
EA1
E1:1
Never adjust
E2:50
With remote control: No
display correction for the
actual room temperature
(only for weather-com-
pensated control units)
E5:0
Never adjust
F1:0
Screed function disabled
(only for weather-com-
pensated control units).
78
Possible change
d6:2
Heating circuit pump starts
at signal "External block-
ing" (subject to coding
addresses 3A, 3b and 3C)
d7:1
Heating circuit pump stops
at signal "External
demand" (subject to coding
addresses 3A, 3b and 3C)
d7:2
Heating circuit pump starts
at signal "External
demand" (subject to coding
addresses 3A, 3b and 3C)
d8:1
Heating program change-
over via input DE1 at exten-
sion EA1
d8:2
Heating program change-
over via input DE2 at exten-
sion EA1
d8:3
Heating program change-
over via input DE3 at exten-
sion EA1
E2:0
Display correction –5 K
to
to
E2:49
Display correction –0.1 K
E2:51
Display correction +0.1 K
to
to
E2:99
Display correction +4.9 K
F1:1
Screed function adjustable
to
in accordance with 6
F1:6
optional temperature/time
profiles (see page 122)
F1:15
Constant flow temperature
20 °C
(cont.)