Ⅲ. ADJUSTMENT
5) SHUTTER CLOSE TIME ADJ
Adjust the Close Timing of each camera's mechanical shutter.
Required Equipment : AE TESTER(LV: 13, 3300K)
<How to adjust>
a...Prepare AE TESTER that can be test up to LV 13.
b...Attach the camera to the AE TESTER.
c...Set the LV to 13.
d...Download the adjustment file and save it to SD memory card.
e...Insert the SD memory card that has the program file and turn on the camera.
f...Adjustment will be done automatically.
g...After completed the adjustment, the camera is turned off automatically.
62