Connection of external liquid supplies
Electrical installation must be carried out
by an authorized personnel!
All optional equipment connected must be
EMC-approved to EN 50081-1 or EN 50082-
2.
Distribution card A can be used to control exter-
37
nal functions, output and input signals.
Outputs (200-240V AC):
38
X71:1,2 Signal "Door locked, program on"
X72:1
0 V (common)
X72:2
Liquid supply 1
X72:3
Liquid supply 2
X72:4
Liquid supply 3
X72:5
Liquid supply 4
X73:1
Detergent box 1 (Y11)
X73:2
Detergent box 2 (Y12)
X73:3
Detergent box 3 (Y13)
X73:4
Detergent box 4 (Y14)
X73:5
Detergent box 2 (Y22)
Inputs:
X70:1,2 Paus/PC5
X70:3,4 Start/Stop
Start/Stop and Pause/PC5 are opto-coupled
inputs. A voltage of 200 - 250 VAC must be con-
nected to X70: 1 and 2, or X70: 3 and 4 to ac-
tivate the function.
Start / Stop is a toggle function. If the machine
is running, the first pulse will stop (pause) the
machine and next pulse will start it again.
Pause / PC5 is a momentary function. Activating
the input will put the machine in pause (or block
heating or extraction for PC5) for as long as the
input is active.
Setting of Pause or PC5 mode, is made in servi-
ce mode. If both parameters PC5 Block Heating
and PC5 Block Extraction are set to "No", the
function will be Temporary Pause in any program
sequence.
Installation
37
38
29
A
B
5331
Card A
Pump
Drain
5233B