INTRODUCTION
europa are wall mounted, room sealed, non condensing
boilers featuring full sequence automatic spark ignition and
fan assisted combustion.
europa 224, europa 228 and europa 232 are low water
content combination gas boilers.
SAFETY
Current Gas Safety (Installation & Use)
Regulations or rules in force
In your own interest, and that of safety, it is the law that this boiler
must be installed by CORGI registered installer or in IE a
competent person, in accordance with the above regulations.
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

ELECTRICITY SUPPLY

The appliance must be efficiently earthed.
Supply 230 V 50 Hz. The fusing should be 3 A.
Connection must be made in a way that allows complete
isolation of the electrical supply, such as a double pole switch,
having a 3 mm (1/8") contact separation in both poles, or a plug
and socket serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.

IMPORTANT NOTES

F This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
F If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
F Under no circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
F If it is known or suspected that a fault exist on the boiler then
it MUST NOT BE USED until the fault has been corrected by
a CORGI registered installer or in IE a competent person.

MINIMUM CLEARANCES

Clearances of 200 mm (7 7/8") above and below, 25 mm (1")
at left, 50 mm (2") at right and 450 mm (17 3/4") at the front of
the boiler case must be allowed for servicing.
After installation the following clearances are allowable during
use, providing the encasing parts are removeable for
servicing:
The bottom clearance can be reduced to 20mm (3/4").
The front clearance can be reduced to 50mm (2").
All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in the Benchmark
Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.
Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the
aims of the programme. Benchmark has been introduced to improve the standards of
installation and commissioning of central heating systems in the UK and to encourage
the regular servicing of all central heating systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

BOILER CONTROLS

A
B
C
A Appliance On lamp
B Domestic hot water temperature control
C Main switch and radiator temperature control
D Boiler reset button
E Lock ---out signal lamp
F Programmer
G System pressure and temperature gauge

TO LIGHT THE BOILER

1 Check that the valves located in the lower part of the boiler
are open.
2 Switch the electricity supply on.
The appliance On lamp A will flash every 4 seconds
(stand ---by condition).
3 If the boiler is to be used for CH and DHW position the
main switch as in the following illustration.
The appliance On lamp A will flash every 2 seconds
(operating boiler).
A
DIAGNOSTIC LIGHTS
The following table gives a summary of the relationship
between each of the possible lamp combinations and their
meaning during normal operaion of the boiler
Normally operating boiler
CH operation
DHW operation
Frost protect operation
Lamp
Flashing lamp, alone
OFF
or simultaneously
with an other lamp.
If the lights sequence observed on the boiler is not included
above then a fault is indicated.
reference should be made to the Installation Instructions or
consult a CORGI registered installer.
D
E
F
G
Flashing lamp,
alternate with
another lamp.