To Light The Boiler; Electricity Supply; Important Notes - IDEAL Minimiser FF 30 User Instructions

Wall mounted, fanned, super efficient gas boilers

Advertisement

The Minimiser is a wall mounted room sealed, super
efficient condensing boiler, featuring full sequence
automatic spark ignition and fan assisted combustion.
Due to the very high efficiency, condensate is produced
from the flue gases and this is drained to a suitable
disposal point through the plastic waste pipe at the right
lower rear of the boiler. A condensate 'plume' will also
often be visible at the flue terminal.
GAS SAFETY (INSTALLATION AND USE)
REGULATIONS, 1994.
In your own interest, and that of safety, it is the law
that this boiler must be installed by a CORGI
registered installer, in accordance with the above
regulations.
It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation
of the boiler.

ELECTRICITY SUPPLY

This appliance must be connected to the supply via a double-
pole switch, fused at 3 A.

IMPORTANT NOTES

THIS APPLIANCE MUST NOT BE OPERATED WITHOUT
THE CASING CORRECTLY FITTED AND FORMING AN
ADEQUATE SEAL.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
Clearances of 145mm (7
3/4") above,
(
") at the sides and 450mm (17
1/4
boiler casing must be allowed for servicing.
If it is known or suspected that a fault exists on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a CORGI registered installer.
2
100mm (4") below, 5mm
") at the front of the
3/4

TO LIGHT THE BOILER

(see illustration on page 3)
Access to the controls is made by swinging the controls pod
door downward.
If a programmer is fitted, refer to separate instructions for the
programmer before continuing.
1. Check that the electricity supply to the boiler is OFF.
2. Ensure that the gas and water supplies to the boiler are
OPEN and external controls are calling for heat.
3. Switch ON the electricity supply to the boiler at the mains
electricity supply socket.
4. Turn the boiler thermostat (B) to position 6.
5. Almost immediately the ignition electrode will operate and
the boiler will ignite.
6. Should the boiler fail to ignite, turn the boiler thermostat to
position 0, wait for 10 seconds then turn back to position 6.
7. Immediately after ignition the 'Burner on' neon (A) will
illuminate.
8. If the 'Burner on' neon (A) fails to light after repeated
attempts, switch off the electrical supply to the boiler and
consult a CORGI registered installer.
WARNING
.
If no frost protection is provided and frost is likely during a
short absence from home, leave the room thermostat and
cylinder thermostat at a reduced setting.
For longer periods, the entire system should be drained -
including the domestic water supply and boiler heat
exchanger.
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time
switch(es) ONLY.
The mains supply should be left switched ON.
TO SHUT DOWN THE BOILER
1. For short periods
Switch OFF the electrical supply to the boiler.
When heating is again required, restore supply to the
boiler.
2. For longer periods
Switch OFF the electrical supply to the boiler or, if a frost
thermostat is fitted, at the time switch.
TO RELIGHT THE BOILER
Repeat the procedure 1 - 8, detailed in 'To light the boiler'.
Minimiser -
User's

Advertisement

loading

This manual is also suitable for:

Minimiser ff 60Minimiser ff 50Minimiser ff 70Minimiser ff 40Minimiser ff 80