40
82.278
41
93.881
42
55.469
43
55.935
44
70.635
45
75
46
66.587
47
65.29
48
64.674
49
74.038
50
61.648
Out Of Range definition:
A ."Out Of Range w/o video display :
(H<30K or H>83K) or (V <55Hz or V>85Hz) or (Pixel Clock > 140M)
B."Out Of Range w/ video display :
(30K<H<83K) and (76Hz< V<85Hz) and (Pixel Clock < 140M)

3.4 Horizontal scanning

Sync polarity
Scanning frequency

3.5 Vertical scanning

Sync polarity
Scanning frequency

3.6 Power input connection

Power cord length
Power cord type

3.7 Power management

The monitor must comply with the Microsoft On Now specification, with two power management states, as
defined by the VESA DPMS document. The monitor must appropriately display the DPMS state.
Mode
Power-On
Off
DC Power Off

3.8 Display identification

In accordance with VESA Display Channel Standard Ver.1.0 and DDC 2B capability
CVT
CVT
VESA-reduced
blanking mode
VESA
VESA
VESA
CVT 2.3MA-R
CVT1.76MW
CVT1.76MW-R
CVT 2.3MA-R
: Positive or Negative
: 30 – 83 K Hz
: Positive or Negative
: 56 - 76 Hz
: 1.8 M
: 3 leads power cord with protective earth plug.
HSYNC VSYNC
On
On
Off
Off
1400x1050
1400x1050
1440x900
1440x900
1440x900
1600x1200
1920x1080
1680x1050
1680x1050
1920x1200
1600x1000
Video
Pwr-cons.
< 37 W(typ..)
active
blanked
< 2 W
N/A
< 1 W
HUDSON 8
74.867
156
84.96
179.5
59.901
88.75
59.887
106.5
74.984
136.75
60
162
59.934 (for
138.5
DVI-D)
59.954
146.25
59.883
119
59.95 (for
154
DVI-D)
59.91
108.5
Indication
Rec. time
Green LED
--
Amber LED
< 3 s
LED Off
79