Sanyo PLV-Z4000 Service Manual page 68

Hide thumbs Also See for PLV-Z4000:
Table of Contents

Advertisement

Electrical Adjustments
No.
Adjustment Item
Group :260 Auto cALIBrAtIoN
0
Execute Calibration
1
Loop Count
2
Auto Status
3
AutoWait
4
CHECK - Tolerance
5
Time out wait
Group:261 Auto cALIBrAtIoN (rGB)
0
OFFSET AREA H START
1
OFFSET AREA V START
2
OFFSET AREA V START
3
GAIN AREA V START
4
Image AREA H WIDTH
5
Image AREA V HIGHT
6
OFFSET Target
7
OFFSET Tolerance
8
Gain Target
9
GAIN Tolerance
10
Image Level Tolerance
Group:262 Auto cALIBrAtIoN (cVBS / S-VIdeo)
0
Y Image Area Start X
1
Y Image Area Start Y
6
Image Area H Width
7
Image Area V Hight
8
Y Target Level
11
Gain Tolerance
12
Image Level Tolerance
Group:264 Auto cALIBrAtIoN (Ycbcr)
0
Y-OFFSET AREA H START
1
Y-OFFSET AREA V STAR
2
CB - OFFSET AREA H START
3
CB - OFFSET AREA V START
4
CR - OFFSET AREA H START
5
CR - OFFSET AREA V START
6
Y - GAIN AREA H START
7
Y - GAIN AREA V START
8
CB - GAIN AREA H START
9
CB - GAIN AREA V START
10
CR - GAIN AREA H START
11
CR - GAIN AREA V START
12
Image AREA H WIDTH
13
Image AREA V HIGHT
14
Y - OFFSET TARGET
15
CB OFFSET TARGET
16
CR OFFSET TARGET
17
Y - GAIN TARGET
18
CB - GAIN TARGET
19
CR - GAIN TARGET
20
OFFSET Tolerance
21
GAIN Tolerance
22
Image Level Tolerance
Initial Value
range
0
0 - 1
8
1 - 30
0
0 / 1 / 9
3
1 - 20
4
1 - 255
20
1 - 255
975
0 - 1000
500
0 - 1000
25
0 - 1000
500
0 - 1000
13
0 - 4095
9
0 - 4095
20
0 - 1023
1
1 - 1023
955
0 - 1023
1
1 - 1023
2
1 - 255
20
0 - 1000
200
0 - 1000
8
0 - 4095
9
0 - 4095
875
0 - 1023
1
1 - 255
2
1 - 255
925
0 - 1000
500
0 - 1000
925
0 - 1000
500
0 - 1000
925
0 - 1000
500
0 - 1000
50
0 - 1000
500
0 - 1000
800
0 - 1000
500
0 - 1000
700
0 - 1000
500
0 - 1000
13
0 - 4095
9
0 - 4095
4
0 - 1023
512
0 - 1023
512
0 - 1023
810
0 - 1023
894
0 - 1023
894
0 - 1023
1
1 - 255
1
1 - 255
3
1 - 255
- 68 -
Input source / description
Auto calibration will execute when the value changes. (For PC
white 100% Adjustment.)
Maximum times of calibration
Read only Auto calibration result
0: End correctly
1 : On Adjustment 9 : End at Error
Wait value
Offset Final check Tolerance
Wait time (sec)
Black Level H
Black Level V
White Level H
White Level V
White / Black Level Width
White / Black Level Hight
Black Level Adjustment Target Value
Black Level Adjustment Tolerance
White Level Adjustment Target Value
White Level Adjustment Tolerance
Image Level Tolerance
Y Image Area Start X
Y Image Area Start Y
Image Area H Width
Image Area V Hight
Y Target Level
Gain Tolerance
Image Level Tolerance
Y-OFFSET AREA H START
Y-OFFSET AREA V STAR
CB - OFFSET AREA H START
CB - OFFSET AREA V START
CR - OFFSET AREA H START
CR - OFFSET AREA V START
Y, CB, CR Area H Widht
Y, CB, CR Area V Widht
OFFSET Tolerance
GAIN Tolerance
Image Level Tolerance

Hide quick links: