No.
Adjustment Item
1
Dither Enable
Group:210 Lamp control
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL0
3
DIMMER_CTRL_LEVEL1
4
DIMMER_CTRL_LEVEL2
5
DIMMER_CTRL_LEVEL3
6
DIMMER_CTRL_LEVEL4
7
DIMMER_CTRL_LEVEL5
8
DIMMER_CTRL_LEVEL6
9
DIMMER_CTRL_LEVEL7
10
DIMMER_CTRL_LEVEL8
11
DIMMER_CTRL_LEVEL9
12
DIMMER_CTRL_LEVEL10
13
DIMMER_CTRL_LEVEL11
14
DIMMER_CTRL_LEVEL12
15
DIMMER_CTRL_LEVEL13
16
DIMMER_CTRL_LEVEL14
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
Group:211 Lamp iris
0
Lamp Iris Close Limit Value
1
Lamp Iris Open Limit Value
4
Lamp IRIS Ave Time
5
Lamp IRIS Move Step
8
Lamp IRIS SW
9
Lamp IRIS Manual
10
Lamp IRIS Close Rate
12
Lamp IRIS Color Adj Open Rate
13
Lamp Iris Repeat mode
14
Repeat Mode Close Value
15
Repeat Mode Open Value
Group:212 costum Gamma coefficient
0
Costum Gamma -R step 0
1
Costum Gamma -R step 512
2
Costum Gamma -R step 1024
3
Costum Gamma -R step 1536
Initial Value
0
0
0
5/0
9/0
14/0
18/0
23/0
27/0
32/14
36/21
41/28
45/35
50/42
54/49
59/56
64/63
69/69
3~16 Dimmer control Lamp mode AUTO1 : Display AUTO1 setting data Enable data exchange
Lamp mode AUTO2 : Display AUTO2 setting data Enable data exchange
Lamp mode NORMAL, ECO : Display AUTO2 setting data Disable data exchange
4
-
-
15
0
-
32
480
1
304
0
256
50/60/70/127/127/0/127
128
0
32
480
18
20
24
26
range
0 - 1
0 : Dither function disable
0 - 1
0 : Auto (User setting) 1 : Manual
0 - 15
Dimmer Control Level ( 0: dark 1: bright)
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 00 (darkest)
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 01
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 02
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 03
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 04
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 05
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 06
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 07
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 08
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 09
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 10
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 11
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 12
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 13
APL level threshold (AUTO1/AUTO2)
0 - 255
Below this data Dimmer level 114
1 - 16
0 - 255
0 - 15
0 - 15
0 - 15
0 - 255
Lamp voltage : Read only
0 - 510
1 - 511
1 - 8
1 - 510
0 - 1
1 - 511
Brilliant / Creative / Pure/ Natural / Living / Dynamic /x.v.Color  
0 - 254
 0 : close 254 : open
0 : close     254 : open
0 - 254
Valur data in not "0", opening and closing of Iris is repeated
according to the set point of No.14, 15.
0 - 8
1 : 2V Sync
2 : 4V Sync
5 : 10VSync
0 - 510
The value set as PWM_Min when the value of No.13 is except 0
1 - 510
The value set as PWM_Max when the value of No.13 is except 0
1 - 512
1 - 512
1 - 512
1 - 512
- 63 -
Electrical Adjustments
Input source / description
1 : Dither function enable
3 : 6V Sync
4 : 8V Sync
6 : 12V Sync 7 : 14V Sync 8 : 16V sync