No.
Adjustment Item
109
Cooling Time
110
Temp Error Cooling Time
111
Average Time
112
Change Normal
113
Dac Change Speed
114
Fan1 Initial Vol
115
Fan2 Initial Vol
116
Fan3 Initial Vol
117
Fan4 Initial Vol
118
Fan5 Initial Duty
119
Fan Keep Time
120
Fan Min Keep Time
121
Shutdown Temp A
122
Shutdown Temp B
123
Shutdown Temp C
124
Shutdown Temp B-A
125
Shutdown Temp C-A
126
Shutdown Time A
127
Shutdown Time B
128
Shutdown Time C
129
Shutdown Time B-A
130
Shutdown Time C-A
131
Control Curve Change Time
132
Lamp Monitor SW
133
Lamp Voltage
134
Lamp Vol Threshold
135
Fan Speed Gain
136
Lamp Keep Time
137
Temp Test Mode
138
Fan Cooling Vol Up
139
Fan Min. Keep Time
140
CF dif. Normal Fan2 Min. Up
141
CF dif. Normal Fan4 Min. Down
142
CF dif. Normal Fan5 Min. Down
143
CF dif. Normal Fan2 Max. Up
144
CF dif. Normal Fan4 Max. Down
145
CF dif. Normal Fan5 Max. Down
146
CF dif. Eco Fan2 Min. Up
147
CF dif. Eco Fan4 Min. Down
148
CF dif. Eco Fan5 Min. Down
149
CF dif. Eco Fan2 Max. Up
150
CF dif. Eco Fan4 Max. Down
151
CF dif. Eco Fan5 Max. Down
152
CF dif. Auto Watt Max. Fan2 Min. Up
153
CF dif. Auto Watt Max. Fan4 Min. Down
154
CF dif. Auto Watt Max. Fan5 Min. Down
155
CF dif. Auto Watt Max. Fan2 Max. Up
156
CF dif. Auto Watt Max. Fan4 Max. Down
157
CF dif. Auto Watt Max. Fan5 Max. Down
158
CF dif. Auto Watt Min. Fan2 Min. Up
159
CF dif. Auto Watt Min. Fan4 Min. Down
160
CF dif. Auto Watt Min. Fan5 Min. Down
161
CF dif. Auto Watt Min. Fan2 Max. Up
162
CF dif. Auto Watt Min. Fan4 Max. Down
163
CF dif. Auto Watt Min. Fan5 Max. Down
164
Auto2 FAN4 Speed Offset
Initial Value
range
3
0 - 15
3
1 - 15
1
0 - 10
0
0 - 1
2
1 - 10
55
0 - 255
40
0 - 255
60
0 - 255
40
0 - 255
113
1 - 510
15
0 - 180
60
0 - 180
15
0 - 100
20
0 - 100
20
0 - 100
20
0 - 100
20
0 - 100
20
0 - 30
10
0 - 30
10
0 - 30
20
0 - 30
20
0 - 30
1
0 - 10
0
0 - 1
- - -
30 - 90
60
50 - 90
300
0 - 1500
90
0 - 255
0
0 - 12
0
0 - 145
0
0 - 15
0
0 - 3150
285
0 - 3150
315
0 - 3150
0
0 - 3150
285
0 - 3150
315
0 - 3150
0
0 - 3150
315
0 - 3150
450
0 - 3150
0
0 - 3150
315
0 - 3150
450
0 - 3150
0
0 - 3150
285
0 - 3150
315
0 - 3150
0
0 - 3150
285
0 - 3150
315
0 - 3150
0
0 - 3150
315
0 - 3150
450
0 - 3150
0
0 - 3150
315
0 - 3150
450
0 - 3150
405
0 - 3150
- 67 -
Electrical Adjustments
Input source / description
0 : always On, 1 : 30sec, 2 : 60sec, 3 : 90sec, - - 15 : 450sec
1 : 30sec, 2 : 60sec, 3 : 90 sec - - - 15 : 450sec
0 : 10sec, 1: 30sec, 3 : 90sec, - - - - 10 : 300sec
Lamp Watage Max
0 : Normal1 : Forced lamp Max
DAC change time (sec)
FAN1 Initial voltage
FAN2 Initial voltage
FAN3 Initial voltage
FAN4 Initial voltage
FAN5 Initial DUTY ratio
FAN Initial voltage keep time (sec)
FAM minimum voltege keep time (sec)
Temprature setting Sensor A at the shutdown (°C)
Temprature setting Sensor B at the shutdown (°C)
Temprature setting Sensor C at the shutdown (°C)
Temprature setting Sensor <B-A> at the shutdown (°C)
Temprature setting Sensor <C-A> at the shutdown (°C)
Temprature setting Sensor A at the shutdown (min)
Temprature setting Sensor B at the shutdown (min)
Temprature setting Sensor C at the shutdown (min)
Temprature setting Sensor <B-A> at the shutdown (min)
Temprature setting Sensor <C-A> at the shutdown (min)
0 : Off 1 : On
Read only
UP : at Cinema filter modo Fan revolution (Normal/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Min)
UP : at Cinema filter modo Fan revolution (Normal/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Normal/Temp. Max)
UP : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Ecol/Temp. Min)
UP : at Cinema filter modo Fan revolution (Eco/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Eco/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Eco/Temp. Max)
UP : at Cinema filter modo Fan revolution (Auto_Max/Temp. Min)
DOWN : at Cinema filter modo Fan revolution Auto_Max/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Min)
UP : at Cinema filter modo Fan revolution (Auto_Max/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Auto_Max/Temp. Miax
UP : at Cinema filter modo Fan revolution (Auto_Min/Temp. Min)
DOWN : at Cinema filter modo Fan revolution Auto_Min/Temp. Min)
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Min)
UP : at Cinema filter modo Fan revolution (Auto_Min/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Max)
DOWN : at Cinema filter modo Fan revolution (Auto_Min/Temp. Miax
FAN4 UP revolution (At Lamp mode Auto2)