Kenmore 153.582400 Use & Care Manual page 29

Table of Contents

Advertisement

(ESM)
ERROR CODE
DIAGNOSTIC LED
E06
6 FLASHES
(Red)
E07
7 FLASHES
(Red)
E08
8 FLASHES
(Red)
E9
9, 10, 11 or 12 FLASHES
(Red)
E10
E11
E12
* These instructions are brief and are intended as guidance for a qualifi ed service technician. If you lack the skills that are necessary
to perform these procedures, call the Sears Service Center for assistance (1-844-553-6667).
(ET)
INDICATES
Electronic Thermostat (ET) failure
(Internal processor).
Lower thermistor sensor failure.
Energy Saver Module (ESM)
failure.
Electronic Thermostat (ET) error
CORRECTIVE ACTION*
1. Turn off electrical power at the breaker. Now turn on electrical
power to see if error clears. If error has not cleared, replace Elec-
tronic Thermostat (ET).
2. Turn on electrical power at breaker.
1. Turn off electrical power at the breaker.
2. Check electrical connections at Electronic Thermostat (ET).
3. Replace Lower Thermistor Sensor.
4. Turn on electrical power at breaker.
1. Turn off electrical power.
2. Check wires at the interface module for damage.
3. If this 8 flashes condition continues, replace module (ESM).
4. See "Overriding The Energy Saver Module (ESM)" on page 19.
Unplug the Electronic Thermostat (ET) as described. NOTE:
Electronic Thermostat (ET) will continue to be operate. Hot water
will still be available.
5. Turn on electrical power at breaker.
1. Turn off electrical power.
2. Check wiring at Electronic Thermostat (ET) for damage.
3. Turn on electrical power at breaker.
4. If this code flashes condition continues, replace the Electronic
Thermostat (ET).
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.582500

Table of Contents