20 SIDE FLUE ASSEMBLY - Exploded View
1. An optional flue duct extension kit is
required for wall thicknesses greater
than:
504mm (19
")
- LHS flue
7/8
380mm (15")
- RHS flue
Refer to Frame 10.
2. When cutting the ducts
always use the cardboard
support cutting aid
provided.
21 WALL MOUNTING TEMPLATE (Side Flue)
IMPORTANT.
For direct mounting (frame on wall) choose one black dot in each group.
If using the stand-off channels choose one circle in each group.
Use stand-off channels for the boiler to be flush with 300mm deep units.
Care MUST be taken to ensure the correct holes are drilled.
Note.
When marking off the flue allow for the
stand-off channels if using them. Read
the notes on the template.
1. Tape template into the selected
position.
2. Ensure squareness by hanging a
plumbline, as shown.
3. Mark onto the wall the following:
a.
The 6 wall mounting plate
screw positions (choose one
from each group).
b. Extended the centre line as
shown. Mark the flue duct
centre from the corner (see
diagram and template).
Note. Mark the centre of the
hole as well as the
circumference.
4. Remove template from the wall.
Response FF80
- Installation
INSTALLATION
LEGEND
1. Terminal
2. Weather seal
3. Sealing ring
4. Clamping ring
5. Duct assembly
6. Flue turret
7. Turret clamp
8. M5 x 10 pozi-hex screw
9. No. 8 x 8 fixing screw
21