Error Messages - Philips LTC 8100 Series Installation Instructions Manual

Allegiant microprocessor-based switcher/control systems
Table of Contents

Advertisement

20

ERROR MESSAGES

Error 01 - Invalid camera request
The camera number entered from the keyboard does not exist. If
using the optional LTC 8059/00 Master Control Software or the
LTC 8850/00 Graphical User Interface software, make sure the
number exists in the Camera Identification Table. Download the
table to be sure.
Error 02 - Invalid monitor request
The monitor number entered from the keyboard does not exist.
Error 03 - Locked remote device
The remote device requested cannot be controlled because it is
locked by a user with equal or higher priority. Check with the
other users or request that a higher priority user unlock the
remote device.
Error 04 - Monitor locked
The monitor requested cannot be accessed because it is locked by
a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the monitor.
Error 05 - Remote device access restricted
Remote locked out by Remote Lock Out Table.
Error 06 - Monitor Access Restricted
Monitor locked out by Monitor Lock Out Table.
Error 10 - Access denied
A function was requested for which your user priority is too low.
Only a Priority 2 user or a supervisor with Priority 1 may access
this function.
Error 11 - Access denied
A function was requested for which your user priority is too low.
Only a supervisor with Priority 1 may access this function.
Error 15 - Invalid user function
The function number requested from the keyboard is invalid.
Refer to the User Function Table for a listing of the valid user
function numbers.
Error 20 - Acknowledge denied
The ACKNOWLEDGE button has been pressed by a user
without the authority to acknowledge alarms.
Error 21 - Incorrect acknowledge
In order to properly acknowledge an alarm event, the keyboard
must be switched to a monitor that is displaying the alarms.
Error 22 - Acknowledge disabled
Alarms on this monitor can not be acknowledged, because that
capability has been disabled by the system programmer.
Error 23 - Camera not in alarm
The camera displayed on the monitor is not an alarm video; only
alarm-generated video can be acknowledged.
Error 24 - Keyboard not enabled for acknowledge
This keyboard may not acknowledge alarm video on this
monitor; it has been disabled by the system programmer.
Error 25 - Alarm switcher running
Alarm video may only be acknowledged if the alarm switcher is
not running; press HOLD to stop the switcher.
Error 50 - SEQUENCE not available
The user tried to load a switcher sequence that does not exist.
This is a good way to tell from the keyboard which sequence
numbers are unused when desiring to add one.
A request was made to load an ABSOLUTE type sequence
without the keyboard being on one of the monitors in that
sequence. Because inadvertent loading of monitors should be
avoided, the user is required to switch his keyboard to one of the
monitors used by the sequence. The PROGRAM mode may be
used to review what monitors are used in the sequence.
Error 52 - SEQUENCE request
A request was made to load a RELATIVE type sequence on too
high of a monitor number; the monitors used by the sequence
would extend past the highest monitor. Try switching to a lower
monitor number before Loading the sequence.
Error 53 - Switcher empty
The user has tried to control a sequence using the NEXT, PREV,
RUN, or HOLD keys without there being a sequence loaded.
Error 55 - SEQUENCE priority
The switcher sequence being requested or cleared requires
monitors that are in use by a user of equal or higher priority.
Contact a user with higher priority or have the system
administrator clear the monitors in question.
Error 56 - SEQUENCE request
The user has tried to load a sequence that is being edited in the
PROGRAM mode. Once editing is completed, the sequence may
be loaded.
Error 58 - SEQUENCE request
The sequence being requested is a relative sequence, and the user
is only allowed access to absolute sequences.
Error 60 - PROGRAM request
The user has tried to program a sequence that is currently
running. The sequence must first be stopped before any editing
can be performed.
Error 62 - PROGRAM request
The user has tried to program a new sequence when the system is
out of sequence memory space. Delete unused sequences and
then program the new sequence.
Error 63 - PROGRAM request
Some other user is already programming a sequence on this
monitor.