Sanyo SAP-CMRV1923GJH Technical & Service Manual page 13

Table of Contents

Advertisement

Outdoor Unit
SAP – CMRV2423GJH
When cooling
When heating
When defrosting
Outdoor
heat
exchanger
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
CAUTION
3-Room Multi Refrigerant Tubing System Diagram
Four-way valve
Solenoid valve
for hot gas bypass
Muffler
Compressor
Electric expansion
valve
Modulator
Strainer
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Muffler
Main
accumulator
Sub-
accumulator
10
Service valve on
wide tube side
Electric
Service
expansion
valve on
valve
narrow tube
Insulation
Thickness:
Min. 8 mm
Wide tube
Unit: mm
Indoor unit
Thickness:
Min. 8 mm
Narrow tube