2. Ion only operation can be off by pressed ION button again. (2 → 1)
3. It can be changed to remocon setting mode (Auto, Heat, Cool, Dry, Fan) + ion operation by OFF/ON switch. (2 → 4)
4. During ion only operation, if power failure occur, after power resume, ionizer & air-conditioner resumes immediately.
5. After error = 24 times, (about 4h), ion & fan off with Ion LED blinks continuously.
(Detail refer to Ionizer Error detection control.)
b. Operation Mode + Ionizer Operation.
1. Ionising Operation Start Condition
When air-conditioner unit is in "ON" condition (Heat, Cool, Dry, Auto mode) and ION operation button at remote controller
is pressed. Ionizer on & ION LED illuminates. (3 → 4)
Power LED also illuminates.
2. Ionising Operation Stop Condition
When one of the following condition is satisfied, ION operation stops.
a. Stopped by ON/OFF switch.
b. Timer OFF activates.
c. ION operation button is pressed again.
d. ION feedback signal shows error.
3. Ionizer operation status is not memorised after off. After OFF, when operation is "ON" again, air-conditioner operates without
ionizer operation.
However, during Cool mode etc. + ionizer operation, if there is a power failure & then power resume, A/con shall on at that
mode + ionizer operation.
c. Timer during ionizer operation
Refer to case study in next page for detail.
8.3.1.
Ionizer Operation case study
Case 1a: Ionizer only operation (24h real time timer ON)
Case 2a: Operation Mode + Ionizer (24h real time timer ON)
Case 3a: Ionizer only operation (24h real time timer ON)
Case 1b: Ionizer only operation (24h real time timer OFF)
Case 2b: Operation Mode + Ionizer (24h real time timer OFF)
Case 3b: Ionizer only operation (24h real time timer OFF)
35
CS-E15CKP CU-E15CKP5