Troubleshooting

DANGER
Risk of electric shock. Turn off the appliance and re-
move the mains plug prior to performing any care and
maintenance work.
Repair work and work on the electrical components may
only be performed by an authorised customer service.
You can rectify minor faults yourself with the help of the
following overview.
If in doubt, please consult the authorized customer ser-
vice.
Appliance is not running
 Pull on the lever of the trigger gun; the device will
switch on.
 Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
 Check the mains connection cable for damages.
 Motor overloaded, the motor circuit breaker has
tripped.
Turn off the appliance "0/OFF".
Allow the device to cool down for one hour.
Switch on the device and put it into operation again.
If the malfunction occurs repeatedly, have the device
checked by the customer service.
Appliance does not start, motor hums
Voltage reduction due to weak mains supply or when
using an extension cable.
 When switching on, first pull the lever of the trigger
gun and then switch the appliance switch to "I/ON".
Pressure does not build up in the appliance
 Check setting at the spray lance.
 Check water supply for adequate delivery rate.
 Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
 Remove air from appliance before operation.
Switch on the appliance without connection the HP
hose (max. 2 minutes) and run it until the water dis-
charging from the HP outlet is free of bubbles.
Switch off appliance and reconnect HP hose.
Strong pressure fluctuations
 Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
 Check water flow quantity.
Appliance is leaking
 Slight leakage from the appliance pump is normal.
If the leakage increases contact the authorized

customer service.

No detergent infeed
 Use spray lance with pressure regulation (Vario
Power).
Turn the spray lance to "Mix" position.
 Check the settings at the dosage regulator for de-
tergent.
 Check whether the Plug 'n' Clean detergent bottle
is placed into the detergent connection facing
down.
12 English

Technical specifications

Electrical connection
Voltage
Connected load
Protection class
Protective class
Mains fuse (slow-blow)
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Max. Suction height
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Max. flow rate
Detergent flow rate
Recoil force of trigger gun
Dimensions and weights
Length
Width
Height
Weight, ready to operate with
accessories
Subject to technical changes.
Customer Service
Australia
KÄRCHER Pty. Ltd.
40 Koornang Road
Scoresby, Victoria 3179
1800 675 714 (Free Call)
www.karcher.com.au
240
V
1~50
Hz
2,2 kW
IP X5
I
16 A
0,6 MPa
60 °C
10 I/min
1,0 m
13 MPa
16
MPa
2300
psi
8,2 I/min
8,3 I/min
0-0,3 I/min
19 N
404 mm
448 mm
968 mm
20,1 kg

Hide quick links: