Siemens Extraklasse 1300 Instruction Manual And Installation Instructions page 32

Table of Contents

Advertisement

32
q Push up the closing cap (1st) and place the drain
hose back in its holder (2nd).
q Carefully remove the pump cap.
A little residual water will flow out.
q Remove any loose debris / fluff from inside the
pump and clean the pump. The pump impeller
must be able to rotate.
Clean any residual lye or fluff from the thread of the
pump cap and pump housing.
q Attach and tighten the pump cap.
q Insert and close service flap.
To avoid unused detergent from flowing into the drain
during the next wash cycle:
q Pour 1 litre / 1 ¾ pt of water into chamber II.
q Select the "Empty" programme.

Advertisement

Table of Contents
loading

Table of Contents