Olsberg 36/019-2 Instruction Manual

Electric ventilation unit

Advertisement

Quick Links

OLSBERG
Instruction Manual
OLSBERG
Electric ventilation unit

Advertisement

Table of Contents
loading

Summary of Contents for Olsberg 36/019-2

  • Page 1 OLSBERG Instruction Manual OLSBERG Electric ventilation unit...
  • Page 2: Table Of Contents

    Table of Contents Decentralised ventilation ........17 Quality of room air..........17 Energy savings ............17 Easy installation ............. 17 How it works / construction diagram ..... 18 Basic principle diagram .......... 18 General ..............19 Delivery, Packaging, Recycling ......19 Instructions for the Installer..........19 Positioning and Installation ........
  • Page 3: Decentralised Ventilation

    CO - 15. p ollution Easy installation • The distributed apartment ventilation system from OLSBERG can be mounted room- 15. b y- 15. r oom, in combination with any heating system, with minimal installation effort • Retroactive installation in existing apartments is easily possible • Just two small holes in the wall per unit necessary,...
  • Page 4: How It Works / Construction Diagram

    How it works / construction diagram Heat recuperation (W) The OLSBERG electric ventilation unit has two fans at a room temperature of 20°C which simultaneously purge exhausted air from, and in- 15. troduce fresh air to the room. The exhaust fan removes the stale air from the room through a cross-flow heat exchanger.
  • Page 5: General

    In humid rooms, the appli- 15. The packaging of your high- 15. q uality OLSBERG Electric ance may be installed in Protection area 3 (according ventilation unit has been limited to the minimum neces- 15.
  • Page 6: Device- 15. S Ide Preparation For Installation

    Device-side preparation for installation Minimum clearances The ventilation appliance should only be removed from The Electric ventilation unit shall be mounted flush to its packaging near to its place of final assembly. the wall. Following minimum clearances must be ad- 15. hered to (Fig. 3): Note: • from the right- 15. h and side panel Do not lift the appliance out of the packaging by to remove the retractable rotary knob ....
  • Page 7 Wall- 15. m ounting strip Fresh air Exhaust air Area for earthed socket Fig. 2 External dimensions of the appliance min.100 min.100 Fig. 3 Configuration air ducts...
  • Page 8: Assembly

    Assembly Electrical connection The Electric ventilation unit is factory delivered as a Opening the appliance (Fig. 1): plug- 15. i n appliance. Remove the front panel. To do this, push the front panel The cable is at the lower left of the appliance and is approx.
  • Page 9: Circuit Diagram

    Circuit diagram 1) 78/4536.0192 Caution high- 15. v oltage! Unplug the mains plug before accessing the mains connection terminals! B1 Electronics B2 Potentiometer for fan speed B3 Regulator - 15. supplemental heater B4 Frost- 15. p rotection monitor E1 Supplemental heater S1 Switch for - 15.
  • Page 10: Rating Label

    The rating label is found on the sealing panel of the ventilating module (remove the front panel to get at it). Made in Germany 36/019-2 Type number Hüttenstrasse 38 D - 59939 Olsberg Fan rating 8...38W 1/N/PE~ 230V 50Hz Post- 15. w arming 300W •...
  • Page 11: Accessories

    Accessories Round duct standard set; flat duct standard set With the round duct standard set, as well as the flat duct standard set, short, straight outside air connec- 15. tions with exterior grilles (1) can be established. The mounting wall (2) is directly penetrated. The duct set is designed for a maximum wall thickness of 500 mm.
  • Page 12: Operating Instructions For The User

    Operating Instructions Operation mode switch The rear rotary knob in the left side panel switches the for the User operation modes. Closing the fresh air ducts - 15. Off, no fan operation If the appliance is out of operation, the external air ducts - 15.
  • Page 13: Post- 15. W Arming Regulator

    Post-warming regulator Before undertaking any maintenance or cleaning work on the appliance, first remove the front panel (B, Use the rotary knob (1...6) in the right side panel to Fig. 10). To do this it must be pushed approx. 1 cm up- 15. variably adjust the temperature for post- 15. w arming of the wards and the removed towards the front.
  • Page 14: Filter Monitoring And Changing

    Condensate indicator and The parts are to be replaced in the reverse order (see Fig.9) to which they were removed. The following im- 15. emptying the condensate sump portant points are to be complied with here: The condensate indicator (Fig. 9, Pos. 5) is located • The exhaust-air filter (4) (white, filter class EU5/F5) at the bottom of the left hand side panel. The float in sits with its smooth side towards the condensate...
  • Page 15: Procedures To Be Followed

    Wall- 15. m ounting strip Front panel Ventilation module Sealing panel Locking mechanism Spring lock G Floor plate Top panel Fig. 10 Technical Data Procedures to be followed • Do not block the free passage of convected air below Dimensions H x W x D ....595 x 670 x 198 mm the appliance.
  • Page 16 Olsberg GmbH Hüttenstraße 38 59939 Olsberg T +49 2962 805-0 F +49 2962 805-180 info@olsberg.com olsberg.com...