Field Settings
4.2

When 2 Units are Installed in 1 Room

Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different addresses.
FTX Series
(1) Remove the battery cover of the remote controller.
(2) Cut the address jumper.
(3) Press the center of TEMP button and OFF button on the remote controller at the same time.
(4) Select A (address setting) with TEMP
(5) Press FAN button to enter the address setting mode.
(6) Press indoor unit ON/OFF button while the operation lamp is blinking.
(7) Press FAN button on the remote controller for 5 seconds to return to the normal mode.
Caution
Replace the remote controller if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
119
The indoor unit operation lamp blinks for 1 minute.
or TEMP
button.
Jumper
EXIST
CUT
Jumper
(R21822)
OPERATION lamp
Indoor unit
ON/OFF
ON/OFF button
Address
1
2
(R21071)
(R21072)