Forced Cooling Operation

2. Forced Cooling Operation

Conditions
Start
Command
frequency
End
Others
Indoor Unit
FTX Series
FTXV Series
115
Item
The forced cooling operation is allowed when both the following conditions are
met.
1) The outdoor unit is not abnormal and not in the 3-minute standby mode.
2) The outdoor unit is not operating.
Press the forced cooling operation ON/OFF button (SW1) on the indoor unit
for 5 seconds.
09 class: 58 Hz
12/15 class: 30 Hz
The forced cooling operation ends when any of the following conditions is
fulfilled.
1) The operation ends automatically after 15 minutes.
2) Press the forced cooling operation ON/OFF button (SW1) on the indoor unit
again.
3) Press ON/OFF button on the remote controller.
Protection functions have priority over all other functions during forced cooling
operation.
Forced Cooling
ON/OFF button (SW1)
ON/OFF
ON/OFF button (SW1)
(R23005)
SiUS091601E
(R21069)