Dispensing System
Complaint
Wine dripping
Wine divided
Too many bubbles
Cooling system
Complaint
Unit not running
Unit running high
a. Improper door seal
temperature or
continually
Temperature is too
high
Temperature is too
low
Compressor
running but not
cooling
Noisy operation
1 7 6 2 1 S o u t h S u s a n a R o a d , R a n c h o D o m i n g u e z , C a l i f o r n i a 9 0 2 2 1
Possible Causes
a. Solenoid valve seal leak
b. Spout loose
a. Wine tube leak
b. Spout loose
c. Empty bottle
a. Debris in spout
a. Argon/Nitrogen pressure is too
high
Possible Causes
a. Power cord unplugged
b. Power switch off
c. No power to the outlet
d. Incorrect and loose wirings
b. Ambient temperature is too
high
c. Improper condenser air flow
d. Refrigeration system problems
a. Temperature setting is too
high
b. Displayed temperature is
correct but inside temperature
is high
a. Temperature sensor is faulty
b. Unit is iced
c. Power board is faulty
d. Display/Control board is faulty
a. Poor evaporator air flow
b. Faulty evaporator fan
c. Refrigerant leakage
d. Refrigeration system restricted
a. Installation area not firm
b. Screws, nuts, and metal parts
may be loose
c. Fan blade is hitting other parts
d. Fan is faulty
e. Compressor is faulty
i n f o @ v i n o t e m p . c o m
Response
a. Check for debris if constant dripping; use
warm water to flush the system
b. Push the spout to tighten if there is
intermittent dripping
a. Check the wine tube
b. Push the spout to tighten
c. Change the empty bottle out for a full
bottle
a. Clean out debris
a. Replace the pressure regulator
Response
a. Check the power cord
b. Turn the switch on (it will light up when
power is on)
c. Check for power at the outlet and fuse
d. Check the wirings and connections at the
power switch and power board
a. Check the door opening and gasket
b. Check the installation location
c. Check the fan and clearance
d. Call customer service
a. Lower temperature setting
b. Temperature sensor is touching the cold
panel
a. Insert the sensor in a cup of iced water to
see if it displays 32˚F
b. Unplug unit to defrost
c. Change the power board
d. Change the display/control board
a. Check for any restrictions
b. Check to see if the fan is turning
c. Call service technician to check for loss
of refrigerant
d. Call service technician to check for
restrictions
a. Make sure unit is level and on flat, solid
surface
b. Check to see if the noise is coming from
the fan mount, compressor mount or
loose tubing
c. Check the blade clearance
d. Check to see if the fan blade is broken or
if the motor is making noise
e. Call customer service