Air driven

Advertisement

Symptom
Moisture blowing
out of tool
Impacts slowly or
Will not impact
Impacts rapidly
But will not remove
bolts
Does not impact
Revision date: 02/2008
Revision date 10/2015
Possible Cause(s)
1.Water in tank.
1.Drain tank. (See air compressor manual).
Oil tool and run until no water is evident.
Oil tool again and run 1-2 seconds.
2.Water in the air
2-1.Install a water separator/filter.
lines/hoses.
Note: Separators only work properly
when the air passing through the
separator is cool. Locate the
separator/filter as far as possible from
the compressor.
2-2.Install an air dryer.
1.Lack of lubrication.
1.Lubricate the air motor and the impact
mechanism.(See lubrication section of
this manual)
2.Tool regulator set in
2.Adjust the regulator setting of the tool.
wrong position.
3.In-line regulator or
3.Adjust regulators in the air system.
compressor regulator
set too low.
1.Worn impact
1-1 Replace impact mechanism.
mechanism.
1-2 Return impact wrench to your supplier for
1.Worn impact
1-1 Replace impact mechanism.
mechanism.
1-2 Return impact wrench to your supplier for
7
Corrective Action
repair.
repair.