Page 1
Instruction manual & spare parts list IW-PRO 1” IW-PRO ¾” IW-PRO ½” IW-PRO SERIES AIR DRIVEN IMPACT WRENCHES Revision date: 02/2008 Revision date 10/2015...
Page 2
1. General Safety and Operation Instruction 1. Unpacking When unpacking this product, carefully inspect for any damage that may have occurred during transit. Make sure any loose fittings, bolts, etc, are tightened before putting this product into service. 2. This product is a part of a high pressure system and the following safety precautions must be followed at all times along with any other existing safety rules.
Page 3
15. Check air hoses for weak or worn condition before each use. Make sure all connections are secured. Release all pressure from the system before attempting to install, service, relocate or performs any maintenance. 16. Keep all nuts, bolts and screws tight and ensure equipment is in safe working condition. 17.
Page 4
2. Particular Safety Instruction 1. Information of Noise Level (1)The noise level at the operator's position is about: A-weighted sound A-weighted sound Model No.: Uncertainty K pressure level (Lpf) power level (Lw) IW-PRO 1” 107.5(dB) 117.6(dB) 3(dB) IW-PRO 3/4” 105.1(dB) 115.3(dB) 3(dB) IW-PRO 1/2”...
Page 5
4. Instructions (1) On the proper adaptation of the reaction bar to the application. (2) Use only sockets and adapters which are in good condition and are intended for use with power tools. (3) Ensure that the assembly power tool is securely fixed to suspension advice, if used. (4) Adopt a suitable postures to counteract normal or unexpected movement of the power tool due to reaction forces from the power assembly tool.
3.Maintenance Instruction 1. Lubrication Proper lubrication is the owner's responsibility. Failure to lubricate the air tool Properly will dramatically shorten the life of the tool and will void the warranty. This impact wrench requires lubrication before the initial use and before and after each additional use.
Page 7
4. Reconnect the air supply to the impact wrench and run for 20 to 30 seconds. Lubricate the entire impact mechanism by rotating the tool upside down and sideways while running the tool. 5. Remove the screw and hold the oil port hole over a suitable container to allow excess oil to drain.
Page 8
Symptom Possible Cause(s) Corrective Action Moisture blowing 1.Water in tank. 1.Drain tank. (See air compressor manual). out of tool Oil tool and run until no water is evident. Oil tool again and run 1-2 seconds. 2.Water in the air 2-1.Install a water separator/filter. lines/hoses.
Fraser/surrey Gaspe Gros Caouna Halifax Hamilton Harbour Grace Holyro od Kitimat Long Pond Marytown Montreal N anaimo New Instruction manual Westminster Bc Pictou/halifax Pointe Aux Pic.quebec Port Alfred Port Cartie r Port Colborne Port Hawkesbury Port Mellon Port M oody Port Of Quebec Port Weller Powell River Prince Rupert Roberts Bank Saint Jo hn Sarnia, Ontario Sept Iles Seven Islands S orel Souris/...