Closing The Door - Frigidaire FRCF185W User Manual

Table of Contents

Advertisement

TROUBLESHOOTING
PROBLEM
There is too much frost and
ice.
The compressor does not
start immediately after
pressing the FastFreeze, or
after changing the tempera-
ture.
Water flows on the floor.
Temperature cannot be set.
Door is misaligned or inter-
feres with ventilation grill.
The temperature in the ap-
pliance is too low/too high.
If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
14
POSSIBLE CAUSE
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
This is normal, no error
has occurred.
The melting water outlet is
not connected to the evap-
orative tray above the
compressor.
The FastFreeze or Shop-
pingMode function is
switched on.
The appliance is not level-
led.
The temperature regulator
is not set correctly.
The food products' tem-
perature is too high.
The door has been opened
often.
The FastFreeze function is
switched on.
There is no cold air circula-
tion in the appliance.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
3. If necessary, replace the defective door
SOLUTION
Refer to "Closing the door".
The compressor starts after a
period of time.
Attach the melting water out-
let to the evaporative tray.
Switch off FastFreeze or Shop-
pingMode manually, or wait
until the function resets auto-
matically to set the tempera-
ture. Refer to "FastFreeze or
ShoppingMode function".
Refer to "Levelling".
Set a higher/lower tempera-
ture.
Let the food products temper-
ature decrease to room tem-
perature before storage.
Open the door only if necessa-
ry.
Refer to "FastFreeze function".
Make sure that there is cold
air circulation in the appliance.
"Installation".
gaskets. Contact the Authorised Service
Centre.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents