Icom ic-r20 Service Manual page 75

Hide thumbs Also See for ic-r20:
Table of Contents

Advertisement

SOFTWARE ADJUSTMENTS–Continued
ADJUSTMENT
S-METER
11
• Mode
[S-M]
• Connect an SSG to the antenna connector and set as
(1400.1 MHz
Level
FM mode)
Frequency
Modulation
Deviation
• Receiving
(1400.1 MHz
12
• Mode
WFM mode)
• Connect an SSG to the antenna connector and set as
Level
Deviation
• Receiving
S-METER
13
• Mode
[S-M]
• Connect an SSG to the antenna connector and set as
Level
(145.1 MHz
FM mode)
Frequency
Deviation
• Receiving
(145.1 MHz
14
• Mode
• Connect an SSG to the antenna connector and set as
WFM mode)
Level
Deviation
• Receiving
(435.1 MHz
15
• Mode
• Connect an SSG to the antenna connector and set as
FM mode)
Level
Frequency
Deviation
• Receiving
16
• Mode
(435.1 MHz
WFM mode)
• Connect an SSG to the antenna connector and set as
Level
Deviation
• Receiving
(650.1 MHz
17
• Mode
FM mode)
• Connect an SSG to the antenna connector and set as
Level
Frequency
Deviation
• Receiving
(650.1 MHz
18
• Mode
WFM mode)
• Connect an SSG to the antenna connector and set as
Level
Deviation
• Receiving
19
• Mode
(1100.1 MHz
FM mode)
• Connect an SSG to the antenna connector and set as
Level
Frequency
Deviation
• Receiving
(1100.1 MHz
20
• Mode
WFM mode)
• Connect an SSG to the antenna connector and set as
Level
Modulation
• Receiving
*This output level of a standard signal generator (SSG) is indicated as SSG's open circuit.
ADJUSTMENT CONDITION
: FM
: 0.56 µV* (–112 dBm)
: 1400.1 MHz
: ±1 kHz
: ±3.5 kHz
: WFM
: 5.6 µV* (–92 dBm)
: ±52.5 kHz
: FM
: 0.56 µV* (–112 dBm)
: 145.1 MHz
: ±3.5 kHz
: WFM
: 5.6 µV* (–92 dBm)
: ±52.5 kHz
: FM
: 0.56 µV* (–112 dBm)
: 435.1 MHz
: ±3.5 kHz
: WFM
: 5.6 µV* (–92 dBm)
: ±52.5 kHz
: FM
: 0.56 µV* (–112 dBm)
: 650.1 MHz
: ±3.5 kHz
: WFM
: 5.6 µV* (–92 dBm)
: ±52.5 kHz
: FM
: 0.56 µV* (–112 dBm)
: 1100.1 MHz
: ±3.5 kHz
: WFM
: 5.6 µV* (–92 dBm)
: ±52.5 kHz
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
• Push [8 SET] key.
5 - 6