Toptech TT-S-755 Installation Manual

Hide thumbs Also See for TT-S-755:

Advertisement

This manual covers TopTech models:
TT-S-755
Thermostat Applications Guide
D
e
s
c
i r
t p
o i
n
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Multi-stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Table of Contents

Una versión española de este
manual puede ser descargada
en http://toptech.pro1iaq.com
® U.S. Registered Trademark. Patents pending.
Copyright © 2010 Pro1 IAQ, Inc. All rights reserved.
INSTALLATION MANUAL
Power Type
Battery Power
Hardwire (Common Wire)
Yes
Yes
Hardwire (Common Wire) with Battery Backup
Yes
Yes
Yes
Yes
Yes
Yes
Page
A trained, experienced technician
must install this product.
2
3
Carefully read these instructions. You
4
could damage this product or cause a
5
hazardous condition if you fail to follow
6-8
these instructions.
9
10-12
13
Need Help?
For assistance with this product please
visit http://toptech.pro1iaq.com or call our
Customer Care Center toll-free at
1-888-776-1427 during normal business
hours (Mon-Fri 9 AM - 6 PM Eastern)
1
Rev. 1022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TT-S-755 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Toptech TT-S-755

  • Page 1: Table Of Contents

    INSTALLATION MANUAL This manual covers TopTech models: TT-S-755 Power Type Thermostat Applications Guide Battery Power Hardwire (Common Wire) Gas or Oil Heat Electric Furnace Hardwire (Common Wire) with Battery Backup Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or Emergency Heat)
  • Page 2: Installation Tips

    INSTALLATION TIPS Wall locations The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. Do not install thermostat in locations: • Close to hot or cold air ducts •...
  • Page 3: Thermostat Quick Reference

    Getting to know your thermostat Displays the user Days of the selectable setpoint temperature. week and time HOLD is displayed when thermostat program is permanently overridden. Menu Options: Shows different options Low Battery Indicator: Replace batteries when this indicator is shown. +1 will appear in Programmable the display when...
  • Page 4: Subbase Installation

    SUBBASE INSTALLATION Caution: Mercury Notice: Electrical Hazard All of Pro1’s products are mercury free. However, if the Failure to disconnect the product you are replacing power before beginning to contains mercury, dispose of it install this product can cause properly. Your local waste electrical shock or equipment management authority can give damage.
  • Page 5: Wiring

    WIRING Wiring Warning: If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced. In some cases the wiring All components of the control connections will not be color coded. For system and the thermostat example, the green wire may not be connected installation must conform to to the G terminal.
  • Page 6: Technician Setup Menu

    TECHNICIAN SETUP MENU Technician Setup Menu This thermostat has a technician setup menu Configure the installer options as desired using the table below. for easy installer configuration. To set up the thermostat for your particular application: Use the keys to change settings and the NEXT STEP Press MENU button or PREV STEP key to move from one...
  • Page 7 TECHNICIAN SETUP MENU Tech Setup Steps (Continued from the previous page) Program Morning ºF or ºC 12 or 24 Options Recovery Hour Clock Operation This feature turns your Select F for Fahrenheit You can select either a Select GAS for You can configure this system on before the temperature read out...
  • Page 8 TECHNICIAN SETUP MENU Tech Setup Steps (Continued from the previous page) Heat Pump System Gas Auxiliary Stages Cooling Fan Switch for Heat Pump of Heat Delay When turned on the You can configure the This option will turn You can configure the The cooling fan delay system switch for the the heat pump off 45...
  • Page 9: Mounting And Battery Installation

    MOUNT THERMOSTAT & BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place. To insure a solid fit between Note: the thermostat and the subbase: mount subbase to flat wall use screws provided drywall anchors should be...
  • Page 10: Programming The Thermostat

    PROGRAMMING THE THERMOSTAT Set Time Follow the steps below to set the day of the week and current time: Press MENU Press SET TIME Day of the week will be flashing. Use the key to select the current day of the week. Press NEXT STEP The current hour is flashing.
  • Page 11 PROGRAMMING THE THERMOSTAT You can use the table below to plan your customized program schedule if using 5+1+1. Programming Table Setpoint Day of the Setpoint Events Time Temperature (Cool) Temperature (Heat) Week Weekday Wake Leave Return Sleep Saturday Wake Leave Return Sleep Sunday...
  • Page 12: Specifications

    SPECIFICATIONS & CONTACT INFORMATION Specifications The display range of temperature 41ºF to 95ºF (5ºC to 35ºC) The control range of temperature 44ºF to 90ºF (7ºC to 32ºC) Load rating 1 amp per terminal, 1.5 amp maximum all terminals combined ± 1ºF Display accuracy Heating is adjustable from 0.2ºF to 2.0ºF Swing (cycle rate or differential)

Table of Contents