INSTALLATION MANUAL This manual covers TopTech models: TT-N-705 and T705 Power Type Thermostat Applications Guide Battery Power Hardwire (Common Wire) Gas or Oil Heat Electric Furnace Hardwire (Common Wire) with Battery Backup Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or Emergency Heat)
INSTALLATION TIPS Wall locations The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. Do not install thermostat in locations: • Close to hot or cold air ducts •...
Getting to know your thermostat Displays the user Days of the selectable setpoint week and time temperature. Hold is displayed when Button thermostat program is options permanently overridden. System operation indicators: The COOL, HEAT or FAN icon will display when the COOL, HEAT or FAN is on.
SUBBASE INSTALLATION Caution: Mercury Notice: All of Pro1’s products are Electrical Hazard mercury free. However, if the Failure to disconnect the product you are replacing power before beginning to contains mercury, dispose of it install this product can cause properly. Your local waste electrical shock or equipment management authority can give damage.
WIRING Caution: Electrical Hazard Warning: Failure to disconnect the power All components of the control before beginning to install this system and the thermostat product can cause electrical installation must conform to shock or equipment damage. Class II circuits per the NEC Code. Wiring If you are replacing a thermostat, make note of the terminal connections on the...
WIRING DIAGRAMS Power supply Factory-installed jumper. Remove only when installing on 2-transformer systems. Use either O or B terminals for changeover valve. Use a small piece of wire (not supplied) to connect W and Y terminals. Set fan operation switch to electric Optional 24 VAC common connection when thermostat is used in battery power mode.
TECHNICIAN SETUP MENU Gas or Electric Setup Gas: For systems that control the fan during a call for heat, put the fan operation switch to the GAS position. Electric: The thermostat operation switch should be put in the ELEC position. This setting allows the thermostat to operate the fan when the fan relay is connected to the G terminal.
TECHNICIAN SETUP MENU Technician Setup Menu This thermostat has a technician setup menu Configure the installer options as desired using the table below. for easy installer configuration. To setup the thermostat for your particular application: Use the keys to change settings and the NEXT STEP Press MENU button or PREV STEP key to move from one option to another.
MOUNT THERMOSTAT & BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.
PROGRAMMING THE THERMOSTAT Set Time Follow the steps below to set the day of the week and current time: Press MENU Press SET TIME Day of the week will be flashing. Use the key to select the current day of the week. Press NEXT STEP The current hour is flashing.
PROGRAMMING THE THERMOSTAT You can use the table below to plan your customized program schedule. Programming Table Setpoint Setpoint Day of the Temperature Temperature Events Time Week (Heat) (Cool) Weekday Wake Leave Return Sleep Saturday Wake Leave Return Sleep Sunday Wake Leave Return...
SPECIFICATIONS & CONTACT INFORMATION Specifications The display range of temperature 41ºF to 95ºF (5ºC to 35ºC) 44ºF to 90ºF (7ºC to 32ºC) The control range of temperature Load rating 1 amp per terminal, 1.5 amp maximum all terminals combined Display accuracy ±...