Timer changing:
If the system is under timer state, the unit can be turned on/off by ON/OFF button on remote controller. Timer can be reset and the
system will run according to the final setting.
If timer ON and timer OFF are set at the same time under running status of the system, the system will keep the current running status.
When timer OFF reaches, the system will be stopped.
If timer ON and timer OFF are set at the same time under OFF state of the system, the system will keep the current stopping status.
When time ON reaches, the system will start running.
Later, the system will run in setting mode when time ON reached and will be stopped when timer OFF reaches. If the setting time
for timer ON and timer OFF is the same, time OFF previals.
(2) Auto Button
When pressing this button once, the system will start running at auto mode, the indoor fan will run according to the auto
fan speed. The swing motor will run when the indoor fan is running. The system will be stopped when pressing this button again.
(3)Buzzer
Upon energization and operation, the buzzer will give out a beep.
(4)Sleep Function
Under cooling or dehumidifying mode, the setting temperature will automatically increase by 1
function and increase by another 1
run according to this setting temperature.
Under heating mode, the setting temperature wi automatically decrease by 1
function and decrease by another 1
Then the unit will continue to run according to this setting temperature. (this isn't available for cooling only unit)
(5) Turbo Function
It is available to set the turbo function under the heating and cooling modes.
(6) Blow Function
It is available to set the blow function under the heating and cooling modes.
(7) Automatic Control of Fan Speed
Under this mode, the air conditioner can automatically select the speed of indoor fan (high, medium or low) with the change of
ambient temperature.
(8)Swing Motor Control
After being powered on, the swing motor firstly makes the guide louver rotated to position 0 anticlockwise, and the air outlet will
be closed.
After starting the unit, if the swing function has not been set, under the heating condition, the up&down guide louver will be rotated to D position
clockwise. Under other conditions, the up&down guide louver will be rotated to horizontal L position.
When setting the swing function at the time of starting the unit, the guide louver will swing between L and D. The guide louver has
seven kinds of swing conditions: position L, position A, position B, position C, position D, swinging between position L and D, and
stopping in any position from L and D (the included angle of L-D is equiangular)
The guide louver is closed at the position 0 when turing off the unit. The swing action will be only effective when the swing order
is set and the indoor fan is in operation.
Note: When the remote controller is set to be in the position L to D, the position A to C, and the position B to D, the guide louver will
swing between the position of L and D.
after 2 hours . It will increased by 2
Set temperature T
T
preset
T
preset
T
preset
2 hour
1 hour
l
after 2 hours. It will be decreased by 2
1 hour
Over 2 hours
2 hour
T
preset
T
preset
Set temperature
T
preset
one hour after setting of sleep
at all within two hours. Then the unit will continue to
preset
Over 2 hours
one hour after setting of sleep
at all within two hours.
T
preset