Hyundai WSH-071NBE Service Manual page 50

Table of Contents

Advertisement

Model of Outdoor Unit
Product Code
Compressor Manufacturer/trademark
Compressor Model
Compressor Type
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range ( º C)
Condenser
Pipe Diameter (mm)
Rows-Fin Gap(mm)
Coil length (l) X height (H)Xcoil width (L)
Fan Motor Speed (rpm)
Output of Fan Motor (W)
Outdoor
Fan Motor RLA(A)
unit
Fan Motor Capacitor (μF)
Air Flow Volume of Outdoor Unit(m
Fan Type
Fan Diameter (mm)
Defrosting Method
Climate Type
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for the
Discharge Side(MPa)
Permissible Excessive Operating Pressure for the
Suction Side(MPa)
Sound Pressure Level dB (A)
Sound Power Level dB (A)
Dimension (W/H/D) ( mm)
Dimension of Package (L/W/H)( mm)
Net Weight /Gross Weight (kg)
Refrigerant Charge (kg)
Length (m)
Gas additional charge(g/m)
Connecti
Outer Diameter
on Pipe
Max Distance
The above data is subject to change without notice. Please refer to the nameplate on the unit.
3
/h)
Liquid Pipe (mm)
Gas Pipe (mm)
Height (m)
Length (m)
HRH-S091NBE
CA136W0121
PANASONIC
5PS102EAA22
ROTARY
20.9
3.85/3.60
835/850
B160-150-241H
Capillary
Capacitor
-7-43
Aluminum fin-copper tube
Φ9.52
1-1.4
748X508X22
830±30
30
0.23
2.5
1600
Axial fan
400
Auto defrost
T1
I
IP24
3.8
1.2
44
798X540X320
825X580X355
31/34
R410a/0.76
5
20
Φ6(1/4)
Φ9.52(3/8)
5
15
48

Hide quick links: