Message Lists

Warning messages
Symptom
High temp.! Lamp off in
1 min.
Frequency is out of
range!
Please replace the Lamp/
Filter.
Please clean the filter.
Please clean the filter.
Have you finished? Yes
No
Projector temperature is
high. High Altitude
Mode should be "On" if
projector is being used at
high altitude.
Power Saving Mode is
set. Projector will
automatically enter
Standby Mode in 1
minute.
Caution messages
Symptom
x
Not applicable!
Settings Lock enabled.
Cause and Remedy
Turn off the power.
Check to ensure that nothing is blocking the ventilation
holes.
Frequency is out of range. Input a signal that is within the
acceptable frequency range of the unit.
It is time to replace the lamp. Replace the lamp.
Also, replace the air filter too. Restart cleaning the
ventilation holes (intake).
If this message appears again after you replace the lamp and
filter, the lamp replacement process is not complete. Check
the lamp replacement process.
Note
To clear this message, press any button either on the remote
control or the control panel of the unit once.
It is time to clean the air filter. Clean the air filter.
Note
To clear this message, press any button either on the remote
control or the control panel of the unit once.
It is time to clean the air filter. Clean the air filter.
If you cleaned the air filter, select "Yes." If you did not clean
the air filter, select "No."
Check to ensure that nothing is blocking the ventilation
holes.
When using the unit at high altitude, set "High Altitude
Mode" to "On."
Note
When temperature inside the unit remains high, "High
Altitude Mode" is switched to "On" in 1 minute, then the
fan speed increases.
"Power Saving" is set to "Standby."
Note
If no signal is input, the power turns off after 1 minute, and
the projector goes into standby mode.
Cause and Remedy
No signal is input in the selected input. Check connections.
Press the appropriate button.
The operation to be activated by the button is currently
prohibited.
"Settings Lock" is set to "Level A" or "Level B."
45