5) Measure DC voltage at each test point with digital multi-meter, and adjust SFR.
ADJ. ITEM
ADJ. POINT
G2
G0
BRT
CONT
COLOR(PAL)
TINT
6) Observe the wave form at each test point with oscilloscope, and adjust SFR.
ADJ. ITEM
ADJ. POINT
W-BAL (SBR)
W-BAL (SBB)
0±0. 01V
Fig. 4 W-BAL (SBR & SBB)
7) Push the PRGM key and select all RED picture signal on the LCD.
Observe the wave form at the test point with osilloscope, and adjust LPF701
ADJ. ITEM
ADJ. POINT
PAL BURST
8) Turn the power off, and set SW102(NTSC/AUTO/PAL) to NTSC position.
9) Activate TEST MODE, and display the 11 STEP MONOTONE PICTURE. (Fig.2)
TEST POINT
SFR701
G2 (TP1)
SFR702
G0 (TP2)
SFR754
BRT (TP3)
SFR751
CONT (TP4)
SFR752
COLOR (TP5) 3.00 ± 0.05V
SFR731
TINT (TP6)
TEST POINT
SFR705
G (TP7)/
R (TP8)
SFR704
G (TP7)/
B (TP9)
G-LEVEL
R-LEVEL &
B-LEVEL
TEST POINT
LPF701
B (TP9)
Fig.5 PAL BURST
ADJ. VALUE
1. 8 ± 0.05V
0.75 ± 0.05V
2.3 ± 0.05V
2.95 ± 0.05V
3.2 ± 0.05V
ADJ. VALUE
ADJUST R (SFR705) AS SAME
LEVEL TO G. (Fig.4)
ADJUST B (SFR704) AS SAME
LEVEL TO G (Fig.4)
ADJ. VALUE
ADJUST LPF701 AS SAME LEVEL. (Fig.5)
THIS WIDTH BECOMES
NARROWEST
2.0 ± 0.1V
GND
– 15 –