Philips Saeco Exprelia Series Service Manual page 21

Hide thumbs Also See for Exprelia Series:
Table of Contents

Advertisement

EXPRELIA
Functional method for the production of milk-based beverages and circuit cleaning
When the solenoid valves open and let air or hot water/steam through, the following situations
occur:
DC3+DC2
DC2
DC4
STEAM
AIR
STEAM
STEAM
Clean
(steam)
Milk-based
DC2
beverages
(steam)
hot water /
steam
PRESSURE RELIEF VALVE
Saeco International Group
STEAM + AIR = Frothing and heating of frothed milk
STEAM FROM CENTRAL HOLE = Heating of non-frothed milk
STEAM FROM LOWER HOLE = Cleaning of milk circuits
MILK FROM
CARAFE
MILK FROM
CARAFE
MILK IN
CARAFE
DC4
Air
DC3
DC5
DC1
FROTHED HOT MILK
(CAPPUCCINO)
VENTURI
PIPE
HOT MILK
VENTURI
PIPE
CLEAN / RINSE
VENTURI
PIPE
DC1 = pressure relief valve assembly
DC2 = steam valve
DC3 = air valve
DC4 = clean valve (steam)
DC5 = hot water/steam valve