CD PLAYER ADJUSTMENTS
c. ADJUSTMENTS
-d
Adjustment
Measuring
Service
output
Adjustment
,
Item
Adjustment
value
instrument
mode
connection
location
I
(a) Tracking
Oscilloscope
TP102:TE
yes
VR131
Waveform
symmetry
balance
TP 101 :VC
A =B
t
(b) Checking
Check
be
sure
that
the
"eye"
IC131 (23) : RF
_
the "eye"
Oscilloscope
pattern
is at
the
center
of
the
TP 101 :VC
pattern
waveform
and
that
the diamond
shape is clearly defined
(a)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Tracking
balance
adjustment
Connect an oscilloscope
to TP102 (TE) and TP101 (VC).
Short-circuit
pattern.
(@)
Insert the
EXT. power plug. (~)
(POWER
"ON")
Remove the short-circuit
pattern. (@).
( Service
mode:
TRACKING BALANCE )
Set the test disc.
PLAY I PAUSE switch push "ON" twice.
Adjust VR131 so that the oscilloscope's
waveform
is symmetrical,
as shown
in the illustration.
To cancel service mode.
disconnect
the
EXT. power plug from the unit.
~
5 msldiv
am-v.
—.
.
*/*
K
w.>
mm
—/s
1
.
RF
I
.
..:
A=B
I
I
500mVldiv
(b) Checking
the "eye" pattern
(1) Connect an oscilloscope
to IC131 (pin 23) (RF)
and TP101 (VC).
(2) Switch "ON" the POWER.
(3) Load the test disc.
(4) PLAY switch push ON.,
(5) Check to be sure that &be " eye " pattern is at the center of
waveform
and that the diamond
shape is clearly defined.
(6) Press the STOP button-
(7) Switch "OFF"
the DC POWER.
D
-6-