Operation

Connection Plugs

120 VAC, 20 Amp, GFCI Duplex Receptacle
This is a 120 Volt outlet protected against overload by a
20 Amp push-to-reset circuit breaker. Use each socket to
power 120 Volt AC, single phase, 60 Hz electrical loads
requiring up to a combined 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-insulated, 3-
wire grounded cord sets rated for 125 Volts at 20 Amps
(or greater).
Keep extension cords as short as possible to prevent
voltage drop and possible overheating of wires.
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle (rotate to
lock/unlock). Connect a suitable 4-wire grounded cord
set to the plug and to the desired load. The cord set
should be rated for 250 Volts AC at 30 Amps (or greater).
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3600 watts (3.6 kW) of power
at 30 Amps or 240 Volt AC, 60 Hz, single phase loads
requiring up to 7200 watts (7.2 kW) of power at 30 Amps.
The outlet is protected by two 25 Amp (5.5kW) or two 30
Amp (6.5kW) push-to-reset or one 30 Amp 2-pole toggle
switch or two 30 Amp push button to reset (6.5/7.5kW)
circuit breaker.
8

How to Use the Generator

If there are any problems operating the generator, call the
generator helpline at 1-888-431-6871.
vehicle, or in partly enclosed areas such as garages,
EVEN IF doors and windows are open! ONLY use out-
doors and far from open windows, doors, vents, and in an
area that will not accumulate deadly exhaust.
seen or smelled. The gas is poisonous, and if breathed in
sufficient concentrations, can cause unconsciousness or
even death.
erator operation. Do not alter the installation or permit
even partial blockage of ventilation provisions, as this
can seriously affect safe operation of the generator. The
generator MUST be operated outdoors.
render the exhaust system unsafe or in noncompliance
with any local codes and/or standards.
000203
properly installed according to the manufacturers instruc-
tions.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Grounding Generator If Used as Portable
An equipment ground connects the generator frame com-
ponents to ground terminals on the AC output recepta-
cles. This allows the generator to be used as a portable
without grounding the frame as specified in NEC 250.34.
Neutral bonded to frame.
000204
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes,
or ordinances that apply to the intended use of the gener-
ator.
Never operate in an enclosed area or
indoors! NEVER use in the home, in a
The engine exhaust fumes contain
carbon monoxide, which cannot be
Adequate, unobstructed flow of cool-
ing and ventilating air is critical to gen-
The exhaust system must be properly
maintained. Do nothing that might
Always use a battery operated carbon
monoxide alarm indoors. Be sure it is
DANGER
Only use OUTSIDE and
far away from windows,
doors, and vents.
Owner's Manual for Portable Generator
000657