Electrical Adjustments; Tuner Section - Sony CDX-4180 Service Manual

Table of Contents

Advertisement

0 dB = 1 µV

TUNER SECTION

Cautions during repair
When the tuner unit is defective, replace it by a new one because
its internal block is difficult to repair.
FM Center Adjustment
Setting:
SOURCE button
D-BASS switch
Frequency Select switch (E model) : FM 200K
FM RF signal
generator
Carrier frequency: 97.9 MHz
Output lever
: 60 dB (1 mV)
Mode
: mono
Modulation
: 1 kHz, 75 kHz deviation (100%)
FM CENTER
IC1 pin #¶
OUT
(Both side
IC1 pin #¢
of R24.)
Procedure:
1. Adjust IFT4 on TU01 so that the reading on the digital voltmeter
becomes in 0 ± 30 mV.
2. Output an Fcenter 10 dB signal output from FM RF signal
generator so that the LINE OUT REAR jack is –20 dBs.
3. Change the FM RF signal generator frequency and check the
deviation of the frequency on + side and – side when the LINE
OUT REAR jack drops 3 dB. (Both + side and – side is approx.
50 kHz.)
4. Re-adjust IFT4 on TU01 when the difference deviation of the
frequency does more than 10 kHz.
0 dBs
–3 dBs
(fc–10)
Adjustment Location: See page 17.
SECTION 3

ELECTRICAL ADJUSTMENTS

: FMI
: OFF
dummy
antenna
antenna
terminal
50 Ω
set
50 Ω
digital
voltmeter
+
(fc+10)
(kHz)
fc
FM SENS/IF Adjustment
Setting:
SOURCE button
D-BASS switch
Frequency Select switch (E model) : FM 200K
FM RF signal
generator
Procedure:
Adjust for a maximum reading on level meter.
Adjustment Location: See page 17.
AM SENS Adjustment
Setting:
SOURCE n MODE button
D-BASS switch
Frequency Select switch (E model) : AM 10K
AM RF signal
generator
30 Ω
Procedure:
Adjust for a maximum reading on level meter.
Adjustment Location: See page 17.
– 16 –
: FMI
: OFF
dummy
antenna
antenna
terminal
50 Ω
4 Ω
set
50 Ω
SPEAKER OUT
FEB1
87.5 MHz
: AM
: OFF
dummy
antenna
antenna
terminal
15 pF
4 Ω
30 pF
set
SPEAKER OUT
IFT1, 3
1,400 kHz
level
meter
+
level
meter
+

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents