3-Pin Vs. 5-Pin; Master/Slave Mode - Bargeheights LED 54AW User Manual

Hide thumbs Also See for LED 54AW:
Table of Contents

Advertisement

3-pin vs. 5-pin

Some manufacturers use 5-pin XLR connectors for DMX trans-
mission. Don't worry! The two are still compatible. Adapters are
available on the internet and from lighting retailers. If you want
to build your own, here are the proper connections:
Cable Conductor
Shield (Ground)
DMX Data +
DMX Data -
not connected
not connected

Master/Slave Mode

The LED 54AW also has a Master/Slave mode. In this mode you
can set the first fixture in the line to act as the master control-
ler – and up to 32 other fixtures can be connected and will mir-
ror the operation of the first. In this configuration, you do not
need a DMX controller.
Master Fixture
DMX IN
Slave Fixture
©2010 Bargeheights, Inc.
3-pin Female
(output)
Pin 1
Pin 2
Pin 3
DMX OUT
DMX IN
DMX OUT
-
-
Connect the fixtures just as
you would for DMX control.
See the OPERATION sec-
tion of this manual for more
information on how to set up
Master/Slave mode.
5-pin Male
(input)
Pin 1
Pin 2
Pin 3
not connected
not connected
to next fixture