Place cooktop into cutout.
2.
Insert clamping screws into the bracket and secure
3.
cooktop to countertop. Use a wood block to protect
fragile countertop materials.

Electrical Installation

Electrical Requirements

You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junctionbox must be located within 3 feet of the cooktop
connection. It should be easily accessible for service
purposes.
Model
240 V AC,
60 Hz system:
circuit breaker
NEM5466UC
30 Amp
6

Connect Electrical Supply

9
The electrical power supply system should be a 1-phase,
3-wire system with ground connection. Install suitable
junction box (not furnished). An appropriately-sized, UL-
listed conduit connector must be used to correctly attach
the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical Code
and all local codes and ordinances.
Attach flexible conduit to the junction box.
9
Connect the cooktop lead wires to the junction box
supply wires in proper phase:
208 V AC,
black (L1) to black
60 Hz system:
red (L2) to red
circuit breaker
blank copper wire to ground
30 Amp
WARNING
Before installing, turn off at the service panel. Lock
service panel to prevent power from being turned
on accidentally.
WARNING
To reduce the risk of electric shock and fire, do not
use a flexible power supply cord.