Trouble Shooting - EcoSpring ES300 Installation & Owner's Manual

All in one type air-source heat pump water heater
Hide thumbs Also See for ES300:
Table of Contents

Advertisement

When ambient temperature does not meet the heat
pump operational requirement (outside the range -7~43℃ ) for
over 20 hours. "LA" will display at TEMP-SET screen and
ALARM indicator flashes simultaneously to alarm that the
temperature is not suitable for heat pump performance, only
E-heater mode could be selected at such circumstance.
Unit switches to E-heater mode automatically to ensure there
is adequate hot water to be supplied. Note that if change of
mode is done automatically, the desired mode will return
automatically upon unit returning to normal working process.
The light will illuminate in error
Warning Code of disagree with
heat pump mode
Temp.Set

Trouble Shooting

If an error occurs, the buzzer will sound 3 times every minute
and the ALARM indicator will flash fast. Hold CANCEL for 3
seconds to stop the buzzer however the light will keep
illuminating.
Installation & Ownerʻs Manual
18
ALARM
Fig.8-18
Fig.8-19
The light illuminates in error
ALARM
Hold CANCEL key to stop the buzzer.
CANCEL
The error code from the screen of TEMP-SET will display when
a malfunction happens, the system will display error code after
one minute, and when the key is pressed again and the screen
will display set temperature.
Display the error code
TEMP-SET
When a malfunction happens in economy mode, the system
may still be used when switched to E-heater mode. However, in
this case, the system will not reach the expected efficiency.
Error Code Explanation (See t able.8-21 )
WARNING
The covers of the electric element should not be
opened unless by a qualified electrician in order
to prevent electric shock and other dangers.
Fig.8-20
Fig.8-21
ES300 Installation & Owner's Manual
19