Fan Speed Control; Accent Light Control - Montigo L38DF-STN Installation & Maintenance Manual

Hide thumbs Also See for L38DF-STN:
Table of Contents

Advertisement

Disabling Thermostat
Some jurisdictions and bedroom installations require the ther-
mostat to be disabled.
1. Partially take out one battery, see Figure 25j.
2. Insert the battery while holding down the thermostat button.
The remote screen will display 'Clr' while the button is held
down. See Figure 25k.
3. To enable thermostat repeat steps 1-2. The remote screen
will display 'set' while the thermostat button is held down.
Figure 25j.
Figure 25k.
XG0810 - 151126
Operation

Fan Speed Control

The fireplace is equipped with optional hot air circulating fans.
The speed of the fans can be controlled by the Proflame sys-
tem. The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key, see Figure 25, to index
to the fan control icon, see Figure 25l. Use the Up/Down Arrow
Keys to turn on, off, or adjust the fan speed. A single "beep" will
confirm reception of the command.
Figure 25l. Fan Speed Control

Accent Light Control

If the fireplace is equipped with variable accent lights. The ac-
cent light function controls the Accent Lights. To activate this
function use the Mode Key, see Figure 25, to index to the accent
light icon, see Figure 25m.
Pressing the Up Arrow Key will turn the light on at the lowest
setting. Continue pressing up to get brighter. Pressing the Down
Arrow Key will turn the lights down until you get to the off posi-
tion. A single beep will confirm the reception of the command.
Figure 25m. Light Control