Section 8: Installing & Removing The Door - Montigo L38DF-STN Installation & Maintenance Manual

Hide thumbs Also See for L38DF-STN:
Table of Contents

Advertisement

L38DF-ST* Indoor Gas Fireplace
Section 8: Installing & Removing the Door
Removing the door:
The L38DF-ST* doors are removed in a few simple steps. Follow
these instructions below to remove the Horizontal access panel,
unlatch the door buckles and, remove the door. Replace in
reverse order.
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.
Step 1:
Remove the Horizontal cover
by placing fingers in both
finger holes, then pushing
away from you and lifting
out. Place it aside during
maintenance or cleaning.
Install in reverse order.
Figure 23. Removing and installing the Horizontal Access Panel
Step 2:
Locate the Door Buckles.
Figure 23a. Locate the door buckles. Both sides typical.
Step 3:
Locate Door Buckle Tool.
Hand-hold
Figure 23b. Door buckle Tool
Page 24
Installation
Finger Holes
Installed Gas
Valve Cove r
Door Latch Slot
Door Latch Hook
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under
door frame. (as shown)
Figure 23c.
Step 5:
Ensure the tool is
firmly in the lower end
of the slot, (as shown),
Then pull toward you
(Caution: hold the tool
securely).
Figure 23d.
Step 6:
Pull hard if necessary to
release the spring ten-
sion. (Caution: The latch
springs back with force,
hold the tool securely).
Figure 23e.
Step 7:
Remove the tool from
the latch slot. Ensure
the latches are hanging
freely, the hook end is
released from the bottom
of the door. (Repeat all
4-steps for the remaining
latches).
Figure 23f.
1
2
3
4
XG0810 - 151126

Advertisement

Table of Contents
loading

This manual is also suitable for:

L38df-stlL38df-stn-fL38fdf-stl-f

Table of Contents