Section 4: Wiring - Montigo L38DF-STN Installation & Maintenance Manual

Hide thumbs Also See for L38DF-STN:
Table of Contents

Advertisement

L38DF-ST* Indoor Gas Fireplace

Section 4: Wiring

OPTIONAL
BATTERY
PACK
1.5V AA type
1.5V AA type
1.5V AA type
RED
BLACK
1.5V AA type
Page 18
Installation
SPARK
SENSOR
TO ON/OFF
BLUE
RED
WALL SWITCH
6
BLUE
WHITE
OPTIONAL CPI/IPI SWITCH
jumper
YELLOW/GREEN
ORANGE
10
GREEN
4
6
3
4
LED Lights
LED1 - Red LED
LED2 Amber LED
Figure 16. Wiring Diagram for the SIT Proflame 2 Electronic Ignition
'Hi-Lo' Adjustment Knob
Manifold Pressure
Test Connection
Inlet Pressure
Gas Control Knob (Shown in "Pilot" position)
Figure 17. Wiring Diagram for SIT Nova 820 gas and pilot.
X2
X1
X3
X4
X5
X10
X11
X12
X13
SW1
Pilot Adjustment Screw
Models Included
L38DF-STN-F
L38DF-STL-F
GREEN
WHITE
BLACK
To PPO
Power
Models Included
Generator
L38DF-STN
L38DF-STL
Wall Switch
XG0810 - 151126