Cross Technologies 2000-16-3624 Instruction Manual

Power supply/battery charger

Advertisement

Quick Links

Instruction Manual
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB: www.crosstechnologies.com
E-MAIL: info@crosstechnologies.com
Model 2000-16-3624
Power Supply/Battery Charger
September 2015, Rev. 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2000-16-3624 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cross Technologies 2000-16-3624

  • Page 1 September 2015, Rev. 0 Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: Equipment Description

    1.1 Equipment Description The 2000-16-3624 Power Supply/Battery Charger uses a +10VDC to +36VDC input to provide +24VDC @3A and +12VDC @3A outputs used for remote terminals. Additionally the power supply will operate from up to 4 BB-2590 type military batteries when DC input power is not available.
  • Page 4: Block Diagram

    BB-2590 BB-2590 BB-2590 T Y PE T Y PE T Y PE T Y PE FIGURE 1.2 2000-16-3624 Power Supply/Battery Charger Block Diagram DC Input Connector +24 VDC Output Terminal Block Connector, Molex 40 A Maximum Power Switch +12 Output Connector...
  • Page 5: Technical Characteristics

    1.2 Technical Characteristics TABLE 1.0 2000-16-3624 Power Supply/Battery Charger Equipment Specifications* DC Input Characteristics Voltage +10VDC to +36VDC** Input Power 400 Watts Maximum (i.e., 40 Amps with +10VDC input) DC Output Characteristics Voltage/Current +12 VDC @ 3 Amps Maximum** +24 VDC @ 3 Amps Maximum** Load Regulation ±5%...
  • Page 6 1.2 Technical Characteristics Continued... TABLE 1.0 2000-16-3624 Power Supply/Battery Charger Equipment Specifications* Continued I/O Connectors Mating Connectors DC Input - 1701692 (Phoenix Contact) 1967456 - (Phoenix Contact 6–20 AWG Wire) +24VDC Output - Molex 39-30-0020 Molex 39-01-2020 (Contact 39-00-0039) +12VDC Output - D-Sub 9-pin Female...
  • Page 7: Installation

    2.0 Installation 2.1 Mechanical Figure 2.0 shows how the 2000-16-3624 is assembled. DC to DC to DC Converter +12VDC (Charging) +24VDC Dual Dual Dual Dual Battery Battery Battery Battery Charger Charger Charger Charger FIGURE 2.1 Mechanical Assembly 2000-16-3624 Manual_Rev.0 Page 7...
  • Page 8 Figure 2.3 shows the signals and indicators on the side panel. DC Input Connector +24 VDC Output +12 Output Connector Terminal Block. Connector, Molex DB-9 Female 40 A Maximum Power Switch 2 Pin Female RJ-45 Ethernet Connector (Optional) FIGURE 2.3 Side Panel Connections 2000-16-3624 Manual_Rev.0 Page 8 09/17/15...
  • Page 9: Operation

    2.3 Installation / Operation 2000-16-3624 Power Supply/Battery Charger 1. The power switch is shipped with a jumper to turn on the unit. If a remote power switch is desired, remove the jumper and connect a remote power switch to the terminals (Open = Off, Closed = On).
  • Page 10: Alarm Indication

    8 Amps. Charging of the disabled batteries will resume when the power load on the charger allows. 2.4 Alarm Indications TABLE 2.0 2000-16-3624 Power Supply/Battery Charger Alarm States Primary Alarm Indications +24VDC Voltage and/or Current Alarm Alarm LED and +24V LED Flash Simultaneously TABLE 2.0...
  • Page 11: Environmental Use Information

    (A-D). Onboard LEDs illuminate when charging is Enabled and will be extinguished if charging is Disabled. If the Bottom Cover is removed make sure to tightly reinstall all screws. No user serviceable parts inside. 2000-16-3624 Manual_Rev.0 Page 11 09/17/15...
  • Page 12: Shiloh Road Alpharetta, Georgia

    ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 Printed in USA 2000-16-3624 Manual_Rev.0 Page 12 09/17/15...